{"product_id":"imri002-abb-remote-i-o-slave-module","title":"IMRI002  | ABB | Remote I\/O Slave Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB Bailey \u003cstrong\u003eIMRI002\u003c\/strong\u003e Remote I\/O Slave Module is a redundant communication interface designed for the\u003cstrong\u003e \u003c\/strong\u003eInfi 90 Distributed Control System (DCS). It provides a secure and high-availability link between localized I\/O clusters and the primary plant loop, ensuring uninterrupted data exchange even in the event of communication faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003eIMRI002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Remote I\/O Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Bailey Infi 90 DCS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Redundant communication interface for remote I\/O clusters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInputs\/Outputs:\u003c\/strong\u003e 16 inputs \/ 16 outputs (digital\/analog depending on configuration)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Infi-Net plant loop, dual redundant paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –40°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 140 × 140 × 75 mm (approx.)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Sweden\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months (supplier dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote I\/O integration in ABB Bailey Infi 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-availability industrial automation requiring redundant communication paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation, petrochemical, and manufacturing plants with distributed control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the primary function of the IMRI002?\u003c\/strong\u003e A: It acts as a redundant communication bridge between remote I\/O clusters and the Infi 90 plant loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does redundancy improve reliability?\u003c\/strong\u003e A: Dual communication paths eliminate single points of failure, ensuring uninterrupted data exchange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What environments is the IMRI002 suitable for?\u003c\/strong\u003e A: It is designed for harsh industrial conditions, operating reliably from –40°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46454772498622,"sku":"IMRI002","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/abb-immfp12-multifunction-processor-ka4k1clf5p2_2d483ac0-5e12-452f-b0c3-5161b30b5de8.png?v=1772612157","url":"https:\/\/www.autooiltech.com\/products\/imri002-abb-remote-i-o-slave-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}