{"product_id":"ic670mdl740-ge-fanuc-field-control-discrete-output-module","title":"General Electric IC670MDL740 Field Control 16-Point Discrete Output Module","description":"\u003cp\u003eThe General Electric IC670MDL740 is a 16-point discrete output module engineered for the Field Control distributed I\/O system. This unit provides positive logic (sourcing) outputs, specifically designed to interface with 24VDC control devices such as pilot lamps, solenoid actuators, and relay coils. As a compact, DIN-rail mountable component, it is ideal for space-constrained industrial control cabinets requiring reliable, high-density I\/O expansion.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point positive logic discrete output architecture.\u003c\/li\u003e\n\u003cli\u003eSupports a wide operating voltage range of 10-30 VDC (24 VDC nominal).\u003c\/li\u003e\n\u003cli\u003eMaximum output current capacity of 0.5 Amps per channel, with a 4 Amp total module limit.\u003c\/li\u003e\n\u003cli\u003eIndividual status LED indicators for each channel to facilitate rapid diagnostics.\u003c\/li\u003e\n\u003cli\u003eIntegrated fuse protection with a dedicated blown-fuse status indicator.\u003c\/li\u003e\n\u003cli\u003eCompact, modular design compatible with standard Field Control terminal bases.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator \u0026amp; Valve Control:\u003c\/strong\u003e Efficiently drives DC solenoids and pneumatic manifold valves in fluid systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Signaling:\u003c\/strong\u003e Powers pilot lamps, status indicators, and audible alarms on control panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Switching:\u003c\/strong\u003e Ideal for activating interposing relays to control higher-load external equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Suitable for integration into conveyor sorting systems, packaging machinery, and textile equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete, Positive Logic (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Count\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e4.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e200 micro-seconds (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (BIU)\u003c\/td\u003e\n\u003ctd\u003e111 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003eAWG 14-22 (single); AWG 18 (dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Bus Interface Unit (BIU) is powered down before installing or removing the module from the terminal base.\u003c\/li\u003e\n\u003cli\u003eMount the module onto a standard DIN-rail, ensuring secure seating to maintain electrical connectivity.\u003c\/li\u003e\n\u003cli\u003eVerify that the external fuse is properly rated (5 Amp, 250 V, 5x20mm) to protect against output shorts.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges (AWG 14-22) and ensure terminals are tightened to prevent intermittent connections.\u003c\/li\u003e\n\u003cli\u003eMaintain proper spacing for ventilation to prevent thermal buildup within the enclosure.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring away from high-EMI sources, such as VFDs or high-voltage power lines, to prevent signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670MDL740?\u003c\/h3\u003e\u003cp\u003eIt is a discrete output module that provides 16 channels of 24VDC sourcing output for controlling industrial devices like solenoids and relays within a GE Field Control system.\u003c\/p\u003e\u003ch3\u003eCan this module handle AC loads?\u003c\/h3\u003e\u003cp\u003eNo, the IC670MDL740 is designed strictly for DC applications (10-30 VDC). For mixed-voltage requirements, consider a relay output module such as the IC670MDL930.\u003c\/p\u003e\u003ch3\u003eWhat should I do if my load exceeds 0.5A per channel?\u003c\/h3\u003e\u003cp\u003eIf your application requires higher current, refer to the IC670MDL742 (1.0A per point) or the IC670MDL730 (2.0A per point) for higher capacity requirements.\u003c\/p\u003e\u003ch3\u003eHow is the module protected against overcurrent?\u003c\/h3\u003e\u003cp\u003eThe module includes an integrated 5 Amp, 250 V slow-acting fuse with a visual LED indicator to signal when the fuse has blown.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48869593907390,"sku":"IC670MDL740","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_91757c86-e0cd-4fa4-b54f-de738d561cb8.jpg?v=1788924090","url":"https:\/\/www.autooiltech.com\/products\/ic670mdl740-ge-fanuc-field-control-discrete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}