{"product_id":"ic200mdl331-ge-fanuc-versamax-discete-output-module","title":"IC200MDL331 | GE Fanuc | VersaMax Discete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL331\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL331\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for AC signal switching within VersaMax PLC systems. It delivers nominal 120 VAC outputs across eight individually isolated channels, with a maximum current rating of 2.0 A per point and integrated snubber\/MOV protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIC200MDL331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e85 mA max from BIU supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e8 individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e85-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOutput Current per Channel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e0.5 A min, 2.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e20 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1\/2 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e8 channel LEDs, OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSnubber + MOV per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus:\u003c\/strong\u003e Supports deterministic communication cycles within VersaMax architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e Maintains predictable execution timing across multiple modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Compatibility:\u003c\/strong\u003e Flash updates align with VersaMax CPU protocols without requiring module-specific firmware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Optical isolation and MOV suppression reduce cross-channel interference during switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: \u003cstrong\u003eDoes the IC200MDL331 support hot-swap installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Power-down is required before insertion or removal to prevent bus disruption.\u003c\/p\u003e\n\u003cp\u003eQ: \u003cstrong\u003eWhat is the switching delay under redundant NIU configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module maintains a nominal 1\/2 cycle response time; redundancy does not add delay.\u003c\/p\u003e\n\u003cp\u003eQ: \u003cstrong\u003eIs firmware upgrade required for compatibility with newer VersaMax CPUs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The module operates independently of firmware; compatibility is ensured via backplane protocol.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47589242994878,"sku":"IC200MDL331","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ge-fanuc-ic200mdl241-versamax-ac-input-modules-aaqxuy1wjs2.png?v=1759132368","url":"https:\/\/www.autooiltech.com\/products\/ic200mdl331-ge-fanuc-versamax-discete-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}