{"product_id":"honeywell-tk-zlcsr1-controller-rack-module","title":"Honeywell TK-ZLCSR1 Controller\/Rack Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-ZLCSR1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTK-ZLCSR1\u003c\/strong\u003e PLC Module, operates as a dedicated hardware component for power distribution and system interface execution within Honeywell Experion Process Knowledge System (PKS) and C300 controller chassis platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-ZLCSR1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 lbs (0.41 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 \/ Experion chassis slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.2 A @ 5.1 VDC, 0.31 A @ 3.3 VDC, 0.073 A @ 24 VDC, 4 mA @ 1.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eController\/Rack Power \u0026amp; Bus Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion C300 \/ Series C I\/O Rack Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Galvanic Isolation Performance\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-density DCS integration, the TK-ZLCSR1 provides galvanic isolation between external control loops and internal system backplane logic, preventing ground loop propagation across field instrumentation. When deployed alongside process analog input networks, the module interfaces with CJC (cold junction compensation) blocks to maintain thermal reference stability across multichannel thermocouple inputs. Operating across multiple rail voltage levels (5.1 VDC, 3.3 VDC, 24 VDC, and 1.2 VDC), internal filtering circuitry suppresses high-frequency noise spikes and cross-channel thermal drift under severe industrial noise profiles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane voltage rail requirements for the TK-ZLCSR1?\u003c\/p\u003e\n\u003cp\u003eA: The TK-ZLCSR1 draws operational current across four distinct DC rails: 1.2 A at 5.1 VDC, 0.31 A at 3.3 VDC, 0.073 A at 24 VDC, and 4 mA at 1.2 VDC. Ensure the system chassis power supply has sufficient headroom across all specified rails prior to inserting the module.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TK-ZLCSR1 module be hot-swapped during live system operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is permitted only when installed in a compatible redundant rack chassis configured for online insertion and removal (RIUP). Ensure that backplane power connections are seated evenly to prevent transient bus disturbances during live maintenance operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the rack chassis is completely powered down or verify that the system environment conforms to local intrinsic safety \/ non-arcing field standards prior to module installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the designated rack chassis guide rails, sliding the unit firmly backward until the rear backplane connectors engage securely.\u003c\/li\u003e\n\u003cli\u003eTorque all module retaining screws to hand tightness (0.4 to 0.6 Nm) to maintain proper earth grounding through the metal chassis subframe.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring shield terminations: ensure cable shields are grounded at a single point (typically at the cabinet grounding bar) to eliminate ground loop currents.\u003c\/li\u003e\n\u003cli\u003eInspect the 24 VDC power feed and multi-rail backplane voltage integrity with a digital multimeter before commissioning field loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48761094144190,"sku":"TK-ZLCSR1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/TC-IXR061_1200x1200_497bf1d7-7c8d-4250-89a0-fafcdff36c98.jpg?v=1787192413","url":"https:\/\/www.autooiltech.com\/products\/honeywell-tk-zlcsr1-controller-rack-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}