{"product_id":"honeywell-tc-ixr061-input-module","title":"HONEYWELL TC-IXR061 Input Module","description":"\u003cp\u003eConfigured for precise signal acquisition in Experion Process Knowledge System platforms, the \u003cstrong\u003eHoneywell TC-IXR061\u003c\/strong\u003e (\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e: Base module hardware identifier for the Experion C200\/C300 series 6-channel high-resolution analog\/thermocouple input module, equipped with a 20-position terminal block connector interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IXR061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Chassis Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Experion Chassis Slot Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.3 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signal Types\u003c\/td\u003e\n\u003ctd\u003eThermocouples (B, E, J, K, R, S, T, N, C), -12 mV to +30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (1.4 uV typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2546 VDC (channel-to-channel, user-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e120 dB @ 60 Hz, 100 dB @ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 15 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for accurate low-millivolt temperature instrumentation, the TC-IXR061 incorporates internal cold junction compensation (CJC) algorithms paired with robust 2546 VDC channel-to-channel and channel-to-system galvanic isolation. This architecture prevents common-mode noise propagation and ground loops across 4-20 mA HART and thermocouple sensing lines. Open circuit detection functions monitor sensor continuity every 5 seconds, while high common-mode rejection (120 dB @ 60 Hz) ensures measurement stability under noisy process control environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What thermocouple types and voltage ranges are natively supported by the TC-IXR061?\u003c\/p\u003e\n\u003cp\u003eA: The module supports thermocouple types B, E, J, K, R, S, T, N, and C, as well as high-resolution direct millivolt input signals spanning -12 mV to +30 mV.\u003c\/p\u003e\n\u003cp\u003eQ: How fast does the TC-IXR061 refresh field input data across all channels?\u003c\/p\u003e\n\u003cp\u003eA: The module updates all 6 galvanically isolated input channels within 50 milliseconds, featuring a settling time of less than 80 milliseconds to 5% of full scale.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the target chassis or ensure the local area is non-hazardous prior to inserting the TC-IXR061 module into the rack.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the slot guides and push firmly until the backplane connector locks into position.\u003c\/li\u003e\n\u003cli\u003eWire field thermocouple lines to the 20-position terminal block, keeping signal lines separate from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eGround cable shields at a single chassis earth point to prevent ground loop interference across millivolt loops.\u003c\/li\u003e\n\u003cli\u003eVerify cold junction reference stability and sensor continuity within the Experion system software after powering on the rack.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48761095454910,"sku":"TC-IXR061","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/TC-IXR061-20_1200x1200_921bbc01-ca9a-408d-9dc0-44ba8e92a947.jpg?v=1787192408","url":"https:\/\/www.autooiltech.com\/products\/honeywell-tc-ixr061-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}