{"product_id":"honeywell-mu-tamr02-51304477-100-analog-input","title":"Honeywell MU-TAMR02 51304477-100 Analog Input","description":"\u003cp\u003eConfigured for resistance thermal detector signal processing in Experion PKS platforms, the \u003cstrong\u003eHoneywell MU-TAMR02 51304477-100\u003c\/strong\u003e (\u003cstrong\u003eMU-TAMR02\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMU-TAMR02\u003c\/strong\u003e: Base hardware model identifier for the High-Performance Process Manager (HPM) \/ PM RTD analog input module assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e51304477-100\u003c\/strong\u003e: Specific 10-digit manufacturing part number designating the high-accuracy RTD interface board revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR02 51304477-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Process Manager Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PM I\/O Card File Slot Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via PM\/HPM Card File Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e8 milliohm per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-20 ppm per deg C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Non-Damaging Input\u003c\/td\u003e\n\u003ctd\u003e-1 to +2 V @ 100 mA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Excitation Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for accurate temperature instrumentation, the MU-TAMR02 51304477-100 delivers precise RTD signal conversion utilizing a constant 1 mA sensor excitation current. The module architecture features high-stability analog-to-digital conversion with a temperature coefficient under +\/-20 ppm per deg C, preventing thermal drift across variable ambient cabinet environments. Operating alongside 4-20 mA HART and millivolt process loops, internal channel isolation protects backplane processing logic against common-mode noise and input overvoltage conditions up to +2 V continuous.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the measurement resolution provided by the MU-TAMR02 51304477-100 RTD interface?\u003c\/p\u003e\n\u003cp\u003eA: The board digitizes resistance inputs with a resolution of 8 milliohm per bit, enabling high-accuracy temperature calculation across RTD ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What continuous voltage limits can the input channels withstand without physical module damage?\u003c\/p\u003e\n\u003cp\u003eA: The input channels tolerate continuous normal mode inputs ranging from -1 to +2 V at 100 mA without sustaining hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the I\/O card file backplane before inserting or removing the MU-TAMR02 module.\u003c\/li\u003e\n\u003cli\u003eAlign the board edges with the target slot card guides and slide the unit inward until backplane bus contacts lock.\u003c\/li\u003e\n\u003cli\u003eTerminate RTD field wiring to the corresponding termination assembly, ensuring 3-wire or 4-wire lead resistance balancing.\u003c\/li\u003e\n\u003cli\u003eGround cable shields at the single-point cabinet ground bus to eliminate inductive interference across temperature loops.\u003c\/li\u003e\n\u003cli\u003eApply backplane power and verify RTD sensor continuity and resistance readings via system diagnostic software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48761115902142,"sku":"MU-TAMR02 51304477-100","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/HONEYWELL-MU-TAMR02-51304477-100_1200x1200_63ee2fef-5477-4162-ba64-a6f235f76eab.jpg?v=1787192051","url":"https:\/\/www.autooiltech.com\/products\/honeywell-mu-tamr02-51304477-100-analog-input","provider":"AutoOilTech Limited","version":"1.0","type":"link"}