{"product_id":"honeywell-fta-t-21-digital-input-fta","title":"Honeywell FTA-T-21 Digital Input FTA","description":"\u003cp\u003eConfigured for discrete signal acquisition in industrial control architectures, the \u003cstrong\u003eHoneywell FTA-T-21\u003c\/strong\u003e (\u003cstrong\u003eFTA-T-21\u003c\/strong\u003e Field Termination Assembly) provides direct physical\/electrical execution of 16-channel digital input termination for high-voltage logic levels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard terminal assembly form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e While the FTA-T-21 is a discrete input assembly, it supports standard voltage-level signaling derived from secondary instrumentation loops. The termination design ensures high-impedance interfaces for non-intrusive monitoring of field-side logic states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The FTA serves as the interface between 125 VAC\/150 VDC field signals and the DCS backplane. It facilitates the conversion of high-voltage discrete inputs into logic-level signals compatible with Honeywell process controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The assembly utilizes integrated isolation barriers to separate the high-voltage (125 VAC\/150 VDC) field side from the low-voltage control backplane. This is necessary to protect the internal controller logic from potential overvoltage transients originating in the field-side distribution network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The robust mechanical design minimizes thermal heat transfer from field-side connections, ensuring that neighboring high-precision analog modules in the rack maintain accurate reference temperatures for thermocouple CJC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FTA-T-21 be used for both 125 VAC and 150 VDC inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The input stage is designed to accommodate both 125 VAC and 150 VDC nominal voltage levels. Ensure the system software is configured correctly for the specific signal type to avoid erroneous state transitions.\u003c\/p\u003e\n\u003cp\u003eQ: Is this FTA compatible with live insertion\/removal?\u003c\/p\u003e\n\u003cp\u003eA: The module is not intended for hot-swapping. Isolate all field power sources and verify that the associated DCS input modules are in a safe maintenance state before engaging or disengaging the FTA from the rack or terminal interface to prevent electrical arching.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the assembly to the designated mounting surface within the industrial cabinet. Ensure the unit is installed with adequate clearance for wiring paths to prevent mechanical stress on the terminal connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the cabinet earth bus using a low-impedance conductor. Proper grounding is mandatory to maintain the safety isolation ratings and to provide a reference for the assembly's surge protection components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring using the appropriate torque settings for the terminal screws. Maintain at least 150 mm of physical separation between the 125 VAC\/150 VDC input wiring and low-voltage control signal lines to mitigate inductive noise coupling and cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48009938141374,"sku":"FTA-T-21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-08_10-31-04_b09222e0-0dde-40cd-8a76-5eae216117fa.png?v=1783481580","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fta-t-21-digital-input-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}