{"product_id":"honeywell-fta-t-18-fail-safe-digital-input-module","title":"Honeywell FTA-T-18 Fail-Safe Digital Input Module","description":"\u003cp\u003eConfigured for high-integrity signal acquisition in safety-instrumented systems, the \u003cstrong\u003eHoneywell FTA-T-18\u003c\/strong\u003e (\u003cstrong\u003eFTA-T-18\u003c\/strong\u003e Fail-Safe Digital Input Module) provides direct physical execution of discrete sensor monitoring. The module serves as the primary \u003cstrong\u003eFTA-T-18\u003c\/strong\u003e Fail-Safe Digital Input Module utilized to execute gas and flame detector interfacing across Honeywell Fail-Safe Controller (FSC) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.87 kg (1.9 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 80 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Digital Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 % full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Safety and SIS Metrics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e The FTA-T-18 incorporates galvanic isolation barriers between the field-side signaling and the FSC backplane. This design ensures that ground potential differences or transient surges originating from field-mounted gas detectors do not propagate into the safety controller, maintaining the integrity of the 2oo3 architecture and preventing common-mode failure events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe State Execution:\u003c\/strong\u003e The module is engineered to enforce a defined fail-safe state upon the detection of internal component faults or loss of input signal validity. It continuously monitors for line faults (open\/short circuits) in the connected flame detection loops, ensuring that the system transitions to a secure state without requiring operator intervention in the event of a field-side malfunction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FTA-T-18 be hot-swapped while the safety system is operational?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for use in FSC systems; however, hot-swapping procedures must strictly adhere to the facility's safety manual. The control software must be informed of the module removal to prevent the FSC from triggering a system trip due to the unexpected loss of input data.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle high-frequency transients on input channels?\u003c\/p\u003e\n\u003cp\u003eA: The module features integrated hardware-level filtering and debounce logic to reject high-frequency EMI\/RFI transients typical of industrial environments. This ensures that only validated state transitions are reported to the controller, preventing false alarm activations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate the shields of field-side signal cables at the designated safety earth bus within the cabinet. Ensure the shield is continuous and maintained as close as possible to the terminal block to minimize the loop area for incoming electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Tightening:\u003c\/strong\u003e Secure all field connections to the terminal block using the manufacturer-specified torque. High-resistance connections in a 24 VDC loop can cause localized heating and inconsistent voltage levels, which may compromise the +\/- 0.05 % repeatability metric.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Clearance:\u003c\/strong\u003e The module is rated for an extended temperature range of -40 to +85 deg C. Ensure that the installation location within the safety cabinet provides adequate clearance from heat-generating components to maintain the thermal stability required for precision signal processing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47908342595774,"sku":"FTA-T-18","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-02_15-58-39_7fd387ea-63e1-40d2-a65e-ab1b3119e709.png?v=1783065993","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fta-t-18-fail-safe-digital-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}