{"product_id":"honeywell-fta-e-02-fail-safe-digital-output-fta","title":"Honeywell FTA-E-02  Fail-Safe Digital Output FTA","description":"\u003cp\u003eConfigured for high-integrity discrete control in safety and automation platforms, the \u003cstrong\u003eHoneywell FTA-E-02\u003c\/strong\u003e (\u003cstrong\u003eFTA-E-02\u003c\/strong\u003e Field Termination Assembly) provides direct physical\/electrical execution of 24-channel relay-based output switching and galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-E-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 x 11.4 x 6.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e24 Channels (Relay Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The FTA-E-02 functions as the physical interface for discrete control loops. While the outputs are relay-based, the assembly is designed to maintain the electrical integrity of adjacent instrument signal paths, ensuring that control operations do not introduce transients into sensitive HART-enabled loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e Integration with the control network is achieved through the backplane interface, enabling the safety system to execute deterministic discrete commands to field actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The assembly provides 1500 VDC of isolation, which is necessary to decouple the field-side relay outputs from the controller backplane logic. This prevents high-voltage spikes from field actuators from propagating into the safety controller logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The assembly's construction utilizes high-thermal-stability materials, ensuring that localized heating from relay energization does not drift the reference voltage used for CJC on neighboring analog temperature input modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FTA-E-02 be used to drive inductive loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 500 mA per channel rating supports standard industrial relay and solenoid loads. However, when switching highly inductive DC loads, external flyback diodes or RC suppression circuits must be installed at the field device to prevent contact welding and extend relay life.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 1500 VDC isolation rating sufficient for direct connection to grid-level power?\u003c\/p\u003e\n\u003cp\u003eA: The 1500 VDC isolation is intended for protection against industrial transients and ground loops within a control cabinet environment. It is not rated for direct connection to grid-level AC power systems; ensure proper step-down or intermediate relay isolation is used for high-power switching.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the assembly onto a DIN-compliant rail or flat surface within the control enclosure. Ensure the mounting allows for adequate airflow around the unit, as high-density relay switching can lead to localized temperature increases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis directly to the cabinet ground grid using a braided copper strap to ensure a low-impedance path for high-frequency noise and ESD discharge. This is mandatory for the reliability of the isolation barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring at the relay output screw terminals. Maintain a physical separation of at least 150 mm from all sensitive communication cables and analog input signals to prevent inductive interference from switching operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48009981624510,"sku":"FTA-E-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-02_15-59-04_910d0c90-be0f-4a42-90af-db767c3dd11d.png?v=1783481431","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fta-e-02-fail-safe-digital-output-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}