{"product_id":"honeywell-fc-tsgas-1624-safe-digital-output-fta","title":"Honeywell FC-TSGAS-1624 Safe Digital Output FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell FC-TSGAS-1624\u003c\/strong\u003e functions as a Safe Digital Output Field Termination Assembly (FTA), designed to interface output modules with field wiring, providing secure termination and compliance with safety instrumented system requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FC-TSGAS-1624\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e Not specified\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Safe Digital Output FTA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e 16 digital output channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Digital output termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Mounted in I\/O nest for Safety Manager systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminal connections with M4 screws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Insulation:\u003c\/strong\u003e Dependent on connected output module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e 1500 V AC\/min (system dependent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Supports backplane supply through Safety Manager architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSIL3 Certification\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe FC-TSGAS-1624 is designed for integration into \u003cstrong\u003eSIL3-certified safety instrumented systems (SIS)\u003c\/strong\u003e. It supports fail-safe state execution by ensuring outputs transition to a defined safe condition under fault scenarios. Galvanic isolation between system and field wiring enhances reliability, while redundancy strategies can be applied at the system level to minimize downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: How many digital output channels does the FC-TSGAS-1624 support? A: The terminal board supports 16 digital output channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Is hot‑swap installation supported? A: Hot‑swap capability is not specified. Modules should be installed or removed with system power down.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does the FTA contribute to system safety integrity? A: The FTA provides secure wiring termination and supports fail‑safe execution, enabling compliance with SIL3 safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount the FTA securely into the designated I\/O nest.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnect wiring to terminal blocks using M4 screws with proper torque.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain shield grounding at a single point to prevent ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeparate digital output wiring from high‑voltage cabling to minimize interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify channel mapping with system software before commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47598819344574,"sku":"FC-TSGAS-1624","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-fc-tsgash-1624-v1-0-field-termination-assembly-module-e1njhxkbhfc_afa9a597-e5ab-4ab7-98de-be815ba4c06c.png?v=1759029915","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fc-tsgas-1624-safe-digital-output-fta","provider":"AutoOilTech Limited","version":"1.0","type":"link"}