{"product_id":"honeywell-fc-rusfdu-02-redundant-universal-safe-field-device-unit","title":"Honeywell FC‑RUSFDU‑02 Redundant Universal Safe Field Device Unit","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell FC‑RUSFDU‑02\u003c\/strong\u003e serves as a universal safe field distribution unit, acting as the primary interface between field instrumentation and the Honeywell Safety Manager controller. It supports redundant configurations, ensuring continuous operation even in case of hardware faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e FC‑RUSFDU‑02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Redundant Universal Safe Field Device Unit (FDU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Honeywell Safety Manager \/ Safety Manager SC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Channels:\u003c\/strong\u003e 32 universal safe channels (configurable as DI, DO, AI, AO)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity:\u003c\/strong\u003e SIL 2 \/ SIL 3 (IEC 61508\/61511 compliant)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 120\/230 VAC feeders, up to 9 A field load at 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e Redundant Ethernet 100 Mbaud RIO link to Safety Manager\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Galvanic isolation between field signals and system bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –40 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40 °C to +85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e 5–95% RH, non‑condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 600 × 600 × 210 mm cabinet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 560 g (net), shipping ~1.5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, IEC standards; Class I Div 2 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRedundant Architecture:\u003c\/strong\u003e Dual‑redundant design ensures fault‑tolerant operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUniversal I\/O:\u003c\/strong\u003e Configurable channels for digital input\/output and analog input\/output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets SIL 2\/SIL 3 requirements for mission‑critical safety systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e Galvanic isolation protects against surges and ground loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Durability:\u003c\/strong\u003e Operates reliably in extreme temperatures and harsh conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Integrated self‑diagnostics and LED indicators for quick fault detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Applications:\u003c\/strong\u003e Ideal for refineries, chemical plants, and power utilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47578594214078,"sku":"FC‑RUSFDU‑02","price":620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-fc-tuio11-safety-universal-i-o-module-jgy0ecqewpg.png?v=1759044437","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fc-rusfdu-02-redundant-universal-safe-field-device-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}