{"product_id":"honeywell-fc-iobus-cpio-i-o-bus-module","title":"Honeywell FC-IOBUS-CPIO I\/O BUS Module","description":"\u003ch3 data-path-to-node=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003eHoneywell FC-IOBUS-CPIO\u003c\/b\u003e serves as the primary \u003cb data-path-to-node=\"2\" data-index-in-node=\"50\"\u003eFC-IOBUS-CPIO\u003c\/b\u003e I\/O BUS Module utilized to execute high-speed deterministic communication across Honeywell Safety Manager platforms. The unit functions as the core communication interface bridge, linking the central processing safety controllers directly to the distributed remote and local input\/output subracks via a dedicated, fault-tolerant safety I\/O bus network.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e: FC-IOBUS-CPIO\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: Honeywell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eOrigin\u003c\/b\u003e: United States \/ Netherlands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e: 1.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e: Standard Safety Manager controller slot form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eOperating Temp\u003c\/b\u003e: -40 to 70 deg C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eSupply Voltage\u003c\/b\u003e: 5 VDC \/ 24 VDC internal backplane draws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eInterface Protocol\u003c\/b\u003e: Dedicated Safety Manager I\/O Bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eBaud Rate\u003c\/b\u003e: High-speed deterministic bus velocity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,9,0\"\u003e\u003cb data-path-to-node=\"4,9,0\" data-index-in-node=\"0\"\u003eStatus Indicators\u003c\/b\u003e: Front panel LED diagnostics for communication and module status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eChannel-to-Channel Isolation and Process Loops\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis module features embedded optoelectronic galvanic barriers to enforce comprehensive channel-to-channel isolation parameters between the high-speed processing logic circuits and the external bus lines. This isolated network layout prevents electrical transient propagation and limits common-mode ground loop noise from corrupting data frames, preserving data integrity and stabilizing the timing of adjacent 4-20 mA HART loop protocol parameters traversing the shared backplane framework.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003eQ: Does this I\/O bus module support redundant configuration modes within the Safety Manager chassis? A: Yes, the hardware supports 2oo3 or dual-redundant configurations, enabling automatic, zero-delay switching latency to the secondary module if a communication fault or hardware error is registered on the primary bus link.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: Can the bus cables be connected or disconnected from the module while the system is powered? A: Live connection or disconnection of the I\/O bus ports is permitted only under verified non-hazardous conditions. Breaking an active communication link in an explosive atmosphere can induce electrical discharge risks or trigger an instantaneous fail-safe state execution.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003eInsert the module into its assigned slot within the central safety controller subrack. Engage the top and bottom ejector handles completely to seat the high-density pins into the backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003eSecure all external I\/O bus communication cables using the integrated mechanical thumb screws to prevent vibration from causing intermittent signal dropouts or contact resistance variations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003eRoute the communication bus cables through dedicated low-voltage wire trays, ensuring a minimum separation distance of 300 mm from high-voltage AC lines and variable frequency drive outputs to eliminate electromagnetic cross-coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47596082299070,"sku":"FC-IOBUS-CPIO","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-fc-io-0001-v1-1-i-o-extended-module-iud2oqwyjqg.png?v=1759055778","url":"https:\/\/www.autooiltech.com\/products\/honeywell-fc-iobus-cpio-i-o-bus-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}