{"product_id":"honeywell-dc-taox61-experion-series-c-analog-output-iota-module","title":"Honeywell DC-TAOX61 Experion Series C Analog Output IOTA Module","description":"\u003cp\u003eConfigured for high-density analog output signal distribution in Experion Series C control platforms, the \u003cstrong\u003eHoneywell DC-TAOX61\u003c\/strong\u003e (\u003cstrong\u003eDC-TAOX61\u003c\/strong\u003e Analog Output IOTA Module) provides direct physical\/electrical execution. It serves as the physical Input Output Termination Assembly (IOTA) carrying 16-channel redundant or non-redundant analog current loop outputs from C300 controllers to field control elements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC-TAOX61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series C IOTA Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external \/ Backplane loop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA Analog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eExperion Series C I\/O Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eField Loop Communications and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell DC-TAOX61\u003c\/strong\u003e assembly incorporates channel-to-channel isolation parameters designed to protect control system electronics from field earth faults and voltage transients. Built to handle bi-directional 4-20 mA HART loop protocol signaling, the terminal assembly passes high-frequency digital communication signals transparently to field actuators and control valves without introducing attenuation or phase distortion into the primary analog control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DC-TAOX61 IOTA support redundant Analog Output module configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the DC-TAOX61 terminal assembly is designed to accept dual Series C Analog Output modules to provide redundant field loop execution without signal interruption.\u003c\/p\u003e\n\u003cp\u003eQ: What protection mechanisms are integrated on individual output channels of the DC-TAOX61?\u003c\/p\u003e\n\u003cp\u003eA: Each terminal pathway includes current-limiting circuitry and transient surge suppression to protect the base assembly against accidental field short circuits or high-voltage spikes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the DC-TAOX61 IOTA assembly onto the vertical DIN-rail system inside the Series C enclosure cabinet.\u003c\/li\u003e\n\u003cli\u003eSecure the retaining screws at the top and bottom of the assembly board to ensure solid mechanical contact with the cabinet frame.\u003c\/li\u003e\n\u003cli\u003eConnect the primary cabinet grounding strap to the dedicated protective earth (PE) ground lug on the IOTA base plate.\u003c\/li\u003e\n\u003cli\u003eRoute field control loop wiring through wire channels, maintaining a minimum 50 mm separation from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA analog output field pairs into the screw terminal blocks, securing cable shields to the cabinet shield grounding bus bar.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48779710824638,"sku":"DC-TAOX61","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/CC-TUIO01_c34642b0-6e5c-4c7f-a8ab-7072bb0c689f.png?v=1787538530","url":"https:\/\/www.autooiltech.com\/products\/honeywell-dc-taox61-experion-series-c-analog-output-iota-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}