{"product_id":"honeywell-cc-tuio11-universal-input-output-iota-redundant","title":"Honeywell CC-TUIO11 Universal Input Output IOTA Redundant","description":"\u003cp\u003eConfigured for high-density signal distribution and power routing in Experion PKS DCS platforms, the \u003cstrong\u003eHoneywell CC-TUIO11\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TUIO11\u003c\/strong\u003e Universal Input Output I\/O Termination Assembly (IOTA), provides direct physical\/electrical execution. It handles field wiring interfacing and power distribution for up to 32 configurable channels when paired with the \u003cstrong\u003eCC-PUIO01\u003c\/strong\u003e I\/O module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TUIO11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18 in (Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem powered via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported (Redundant IOTA Configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O Module\u003c\/td\u003e\n\u003ctd\u003eCC-PUIO01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Channel Isolation Features\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TUIO11\u003c\/strong\u003e incorporates high-performance channel-to-channel isolation and integrated cold junction compensation (CJC) pathing to preserve signal integrity across 32 universal channels. Each terminal block path supports dynamic reconfiguration for 4-20 mA HART loop protocol signals, analog inputs, analog outputs, digital inputs, and digital outputs without physical jumper adjustments. Internal suppression circuits prevent transient surges on field signal lines from propagating into the redundant \u003cstrong\u003eCC-PUIO01\u003c\/strong\u003e controller interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CC-TUIO11 maintain continuous signal processing during module replacement?\u003c\/p\u003e\n\u003cp\u003eA: The redundant CC-TUIO11 assembly provides dual mounting positions for two CC-PUIO01 modules. One module can be removed and replaced without interrupting power or field signal connections on the active channel.\u003c\/p\u003e\n\u003cp\u003eQ: What are the field wiring limits for the 32-channel terminal connections on this IOTA?\u003c\/p\u003e\n\u003cp\u003eA: The screw terminal blocks accommodate field conductors up to 14 AWG. Standard shielding practices require single-point grounding at the primary shield bar on the assembly chassis to eliminate ground loop currents.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the 18-inch CC-TUIO11 assembly securely onto the vertical enclosure carrier chassis using standard mounting hardware.\u003c\/li\u003e\n\u003cli\u003eEnsure the primary ground lug is bonded to the main cabinet protective earth (PE) bar using a low-impedance copper conductor before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eDress the 32 field signal cables through side wire ducts, maintaining at least 50 mm separation from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003eVerify correct seating of field terminal blocks and enforce standard NPT or cable gland strain relief procedures.\u003c\/li\u003e\n\u003cli\u003eAlign and press the CC-PUIO01 primary and secondary modules into the redundant base sockets until retention latches fully engage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48779711512766,"sku":"CC-TUIO11","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/CC-TUIO11_871bb294-ecd6-4d68-a45b-5c20421180de.png?v=1787538088","url":"https:\/\/www.autooiltech.com\/products\/honeywell-cc-tuio11-universal-input-output-iota-redundant","provider":"AutoOilTech Limited","version":"1.0","type":"link"}