{"product_id":"honeywell-cc-paix02-analog-input-module","title":"HONEYWELL CC-PAIX02 Analog Input Module","description":"\u003cp\u003eConfigured for high-density analog signal acquisition in Experion PKS platforms, the \u003cstrong\u003eHoneywell CC-PAIX02\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIX02\u003c\/strong\u003e High Level Analog Input Module) provides direct physical\/electrical execution. It processes up to 16 differential or single-ended high-level voltage and 4-20 mA current signals from transmitters and field instruments, converting physical loop variables into 16-bit digital telemetry over the controller backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series C Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem powered via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Differential \/ Single-Ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5 V, 1-5 V, 0.4-2 V, 4-20 mA (via 250 ohm resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.075% of full-scale (at 23.5 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Differential Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIX02\u003c\/strong\u003e incorporates channel-to-channel isolation architecture designed to suppress high common-mode noise and prevent field-side voltage surges from invading the backplane bus. Supporting differential voltage and 4-20 mA current loop processing, each input channel includes current-limiting circuits for Class 1, Div 2 non-incendive field wiring interfacing without external fuses. Internal hardware filtering eliminates high-frequency noise interference, maintaining signal resolution across dense I\/O cabinet arrangements alongside 4-20 mA HART loop protocol lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the differential input structure of the CC-PAIX02 protect signal integrity on long field cables?\u003c\/p\u003e\n\u003cp\u003eA: Differential inputs reject common-mode noise and ground potential differences between field transmitters and the control cabinet, providing up to 70 dB common-mode rejection (CMRR).\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-PAIX02 module be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-PAIX02 supports live insertion and removal on the Experion Series C carrier chassis without disrupting power or communication on adjacent operational I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the CC-PAIX02 module with the designated card slot on the Experion Series C carrier chassis.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into the backplane connector until top and bottom retention latches engage.\u003c\/li\u003e\n\u003cli\u003eEnsure the companion Input Output Termination Assembly (IOTA) ground lug is bonded to the main cabinet protective earth (PE) bus.\u003c\/li\u003e\n\u003cli\u003eRoute transmitter signal wiring through enclosure raceways, maintaining a minimum 50 mm clearance from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eTerminate twisted shielded pairs at the IOTA screw block terminals, ensuring cable shields are grounded at a single point to prevent ground loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48779717312702,"sku":"CC-PAIX02","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/CC-PAIN0151410069-175_9ed85ebd-7540-4c0f-9f11-789cd2f999a5.png?v=1787536634","url":"https:\/\/www.autooiltech.com\/products\/honeywell-cc-paix02-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}