{"product_id":"honeywell-8u-tdodb1-redundant-digital-output-iota-module","title":"Honeywell 8U-TDODB1 Redundant Digital Output IOTA Module","description":"\u003cp\u003eConfigured for high-reliability digital actuation in Honeywell Experion PKS and TPS networks, the \u003cstrong\u003eHONEYWELL 8U-TDODB1\u003c\/strong\u003e (\u003cstrong\u003e8U-TDODB1\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module drives 32 isolated high-side switch outputs operating across a 10-35 VDC field-supplied voltage range, delivering real-time diagnostics and hot-swappable automatic failover via the IOHIGHWAY backplane bus operating at speeds up to 12 Mbit\/s.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-TDODB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard IOTA Chassis Weight (Approx. 0.65 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 8 IOTA Assembly Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic powered via IOPS unit; Outputs field-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Digital Output (High-Side Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 35 VDC (Field-Supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel, 2 A total per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5 ohm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC between system logic and field circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Switchover Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eIOHIGHWAY at 12 Mbit\/s or 4 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Digital Output Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 8U-TDODB1 module incorporates 500 VDC galvanic isolation barriers to decouple sensitive internal IOHIGHWAY processing logic from high-voltage field-side load spikes and ground potential shifts. Each of the 32 high-side solid-state switching channels is engineered with internal current-limiting and short-circuit protection circuits, preventing localized field wiring faults from propagating across adjacent channels. Integrated real-time diagnostics continuously verify the physical state of active outputs and supply voltages, ensuring seamless execution of redundant failover commands in less than 500 ms without disrupting continuous 24 VDC process control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum redundancy switchover latency during a primary hardware fault?\u003c\/p\u003e\n\u003cp\u003eA: The 8U-TDODB1 executes automatic failover to the secondary redundant path in less than 500 ms upon detecting a primary channel or logic error, preserving field output driver states without missing control cycles.\u003c\/p\u003e\n\u003cp\u003eQ: How is logic power supplied to the module relative to the field output circuits?\u003c\/p\u003e\n\u003cp\u003eA: Module system logic is powered directly via the internal IOPS (I\/O Power Supply) backplane unit, while output load driving current is sourced independently through an external 10-35 VDC field power supply wired to the IOTA terminal assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the 8U-TDODB1 IOTA assembly onto the cabinet DIN rail, verifying that mechanical grounding clips engage fully to establish low-impedance chassis earthing.\u003c\/li\u003e\n\u003cli\u003eRoute external 10-35 VDC field output wiring in separate wire ducts away from high-voltage AC cables and sensitive low-level analog signal lines.\u003c\/li\u003e\n\u003cli\u003eConnect field loop return wires directly to the designated field ground terminal block, verifying that overall cable shielding is tied to clean instrument ground at a single cabinet point.\u003c\/li\u003e\n\u003cli\u003eTorque all field terminal wiring screws to industrial specifications (0.5 to 0.6 Nm) to maintain low-resistance, gas-tight contact across all 32 output channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48791329669310,"sku":"8U-TDODB1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/CC-PAIX01_b3fe353f-cb44-43bb-8413-f62ab8808c32.png?v=1787814266","url":"https:\/\/www.autooiltech.com\/products\/honeywell-8u-tdodb1-redundant-digital-output-iota-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}