{"product_id":"honeywell-8u-taixb1-redundant-analog-input-module","title":"Honeywell 8U-TAIXB1 Redundant Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell 8U-TAIXB1\u003c\/strong\u003e Redundant Analog Input Module is engineered for Experion PKS Series 8 systems, providing high-density analog input capability with redundancy for critical process applications. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e8U-TAIXB1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e Redundant Analog Input Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand New\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Experion PKS, C300 Controller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eProduct Range:\u003c\/strong\u003e Series 8U\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 120 × 145 × 65 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHS Code:\u003c\/strong\u003e 8537101190\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLead Time:\u003c\/strong\u003e In Stock\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMOQ:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 single-ended analog input channels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e Current (2-wire or self-powered transmitters)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Range:\u003c\/strong\u003e 4–20 mA (via 250 Ω resistor)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Converter Resolution:\u003c\/strong\u003e 16 bits\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eModule Current Rating:\u003c\/strong\u003e 110 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Scan Rate:\u003c\/strong\u003e 50 ms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNormal Mode Rejection Ratio:\u003c\/strong\u003e 19 dB @ 60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eFilter Response:\u003c\/strong\u003e Single-pole RC, -3 dB @ 6.5 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCrosstalk (channel-to-channel):\u003c\/strong\u003e -60 dB (dc to 60 Hz)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Input Voltage:\u003c\/strong\u003e ±30 V (no damage referenced to common)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eHardware Accuracy:\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e±0.075% of full-scale @ 23.5°± 2°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% of full-scale (0 to 60°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 1000 VAC RMS or ±1000 VDC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Technique:\u003c\/strong\u003e Icoupler (in IOM)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e Hot-swappable design, redundant architecture, diagnostic LEDs.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eProvides 16 single-ended analog input channels with redundancy for critical applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-resolution 16-bit A\/D conversion ensures precise signal acquisition.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHot-swappable capability allows safe replacement without system shutdown.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRobust galvanic isolation enhances safety and prevents interference.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRedundant design ensures continuous operation in mission-critical environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOil \u0026amp; gas process control requiring redundant analog input acquisition.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower generation facilities monitoring multiple current transmitters.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical and petrochemical plants with high-reliability requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManufacturing automation systems integrating redundant analog inputs for safety-critical processes.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many channels does the 8U-TAIXB1 support?\u003c\/strong\u003e A: It supports 16 single-ended analog input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What input type is supported?\u003c\/strong\u003e A: Current inputs from 2-wire or self-powered transmitters, 4–20 mA range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the module be replaced under power?\u003c\/strong\u003e A: Yes, hot-swappable design supports removal and insertion under power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What isolation method is used?\u003c\/strong\u003e A: Icoupler isolation technology with 1000 VAC RMS or ±1000 VDC galvanic isolation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45961841967294,"sku":"8U-TAIXB1","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-8u-pwsp05-phx-power-supply-module-t5vsic431mv_d49371c4-ad1d-4b77-aba4-e1199f468507.png?v=1769753734","url":"https:\/\/www.autooiltech.com\/products\/honeywell-8u-taixb1-redundant-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}