{"product_id":"honeywell-8c-paon01-analog-output-module","title":"Honeywell 8C-PAON01 Analog Output Module","description":"\u003cp\u003eConfigured for precise analog output signal generation in Experion PKS platforms, the \u003cstrong\u003eHoneywell 8C-PAON01\u003c\/strong\u003e (\u003cstrong\u003e8C-PAON01\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454357-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 \/ Series 8 Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Bus Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Types\u003c\/td\u003e\n\u003ctd\u003eVoltage and current output signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ C300 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PAON01\u003c\/strong\u003e converts internal controller logic directives into driving signals across voltage and current output paths. Operating in connection with 4-20 mA HART loop protocol field devices and actuators, the assembly incorporates internal channel-to-channel isolation networks to suppress common-mode electrical noise, eliminate ground potential loops, and maintain signal integrity between field devices and the backplane logic interface. Thermal management routines stabilize drive circuitry across an operating envelope of -20 to +60 deg C, maintaining loop regulation for downstream final control elements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 8C-PAON01 module compatible with Honeywell C300 controller architectures?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module integrates directly with Honeywell Experion PKS and C300 controller platforms.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical signal formats are supported by the 8C-PAON01 output channels?\u003c\/p\u003e\n\u003cp\u003eA: The module supports both analog voltage and current output signals for field device regulation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous operating thermal boundaries for this assembly?\u003c\/p\u003e\n\u003cp\u003eA: The module is specified for continuous operation within ambient thermal limits of -20 to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower De-energization: Verify that rack backplane power supplies and external loop power sources are de-energized prior to inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eMechanical Seating: Align module side guides with the designated I\/O chassis slot. Press the module inward until internal rear connectors align and lock securely into the carrier bus.\u003c\/li\u003e\n\u003cli\u003eShielding and Grounding: Terminate signal wiring at designated field terminal assemblies. Ensure cable shields are grounded at a single point to the enclosure system ground rail to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003eClearance Considerations: Maintain adequate vertical clearance around the module carrier to permit unobstructed natural convection cooling within the specified operating temperature range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48784478470334,"sku":"8C-PAON01","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/8C-PAINAI_6e4c1877-c472-4dc0-8c5d-36d3de0975c5.png?v=1787647006","url":"https:\/\/www.autooiltech.com\/products\/honeywell-8c-paon01-analog-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}