{"product_id":"honeywell-8c-ip0101-pulse-input-module","title":"HONEYWELL 8C-IP0101 Pulse Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-IP0101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-IP0101\u003c\/strong\u003e Pulse Input Module, operates as a dedicated hardware component for high-accuracy measurement of frequency and pulse signals within Honeywell control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-IP0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e8C-IP0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 8 Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 3.0 W at 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 pulse inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eConfigurable pulse or frequency signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Resolution\u003c\/td\u003e\n\u003ctd\u003e32-bit counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 VDC to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd\u003e5 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-IP0101\u003c\/strong\u003e processes high-speed discrete signal streams for precise flow totalization, turbine speed monitoring, and frequency acquisition. Featuring 500 VDC channel-to-channel isolation across all 8 input channels, the module eliminates ground potential loops and suppresses common-mode electrical noise in high-density industrial control enclosures. Internal 32-bit counter registers evaluate incoming pulse widths down to a 5 us minimum threshold across a frequency range of 0.1 Hz to 100 kHz. Operating in control racks alongside 4-20 mA HART loop protocol instruments, the isolated pulse acquisition circuitry prevents cross-talk and preserves continuous logic execution across an extended operating thermal range of -40 to 70 deg C.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal frequency range is supported by the 8C-IP0101 pulse module?\u003c\/p\u003e\n\u003cp\u003eA: The module acquires configurable pulse and frequency signals spanning from 0.1 Hz up to 100 kHz with a 32-bit counter resolution.\u003c\/p\u003e\n\u003cp\u003eQ: What level of electrical isolation is provided between individual channels?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates 500 VDC channel-to-channel isolation to protect system backplane logic from ground loops and field transient noise.\u003c\/p\u003e\n\u003cp\u003eQ: What are the input voltage parameters for incoming field pulse signals?\u003c\/p\u003e\n\u003cp\u003eA: The 8C-IP0101 accepts field pulse input levels from 5 VDC to 24 VDC, with a minimum detectable pulse width of 5 us.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Disconnection: Fully de-energize the 24 VDC main power supply and external pulse signal wiring before installing or servicing the module.\u003c\/li\u003e\n\u003cli\u003eModule Mounting: Align the circuit board edges with the card guide rails of the Honeywell I\/O carrier rack. Slide the unit in until the rear backplane connectors lock firmly into place.\u003c\/li\u003e\n\u003cli\u003eCable Routing \u0026amp; Shielding: Route high-speed pulse and frequency input cables in separate, dedicated wire ducts away from heavy AC power wiring. Connect cable shields to a single-point system earth ground.\u003c\/li\u003e\n\u003cli\u003eThermal and Environmental Constraints: Maintain adequate airflow within the enclosure to ensure ambient operating conditions remain within -40 to 70 deg C and 5% to 95% non-condensing relative humidity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48784480895166,"sku":"8C-IP0101","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/CC-PAIX01_d8c09115-a5d8-470e-aed2-ea299e8fcebd.png?v=1787646948","url":"https:\/\/www.autooiltech.com\/products\/honeywell-8c-ip0101-pulse-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}