{"product_id":"honeywell-51304920-100-serial-interface-module","title":"Honeywell 51304920-100 Serial Interface Module","description":"\u003cp\u003eConfigured for serial data exchange in TDC3000 DCS platforms, the \u003cstrong\u003eHoneywell 51304920-100\u003c\/strong\u003e (\u003cstrong\u003e51304920-100\u003c\/strong\u003e Serial Interface Module) provides direct physical and electrical execution of RS-232 and RS-485 communication protocols.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304920-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e216 × 160 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The serial interface module architecture supports transparent integration with DCS racks that manage HART-enabled instruments. It ensures that serial-to-digital data mapping occurs without interfering with the analog signal integrity of connected HART loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The module incorporates electrical separation between serial ports to mitigate ground potential differences and common-mode noise. This isolation is necessary when connecting to field instruments situated at varying physical distances from the control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The metal enclosure design ensures optimal thermal dissipation within the DCS rack, maintaining a stable environmental profile that does not degrade the accuracy of nearby thermocouple input modules requiring precise CJC execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module serves as a high-speed gateway, translating serial data frames into deterministic network packets compatible with the TDC3000 infrastructure, facilitating real-time data exchange between legacy serial devices and the controller backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping within the TDC3000 cabinet?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swap capability is dependent on the specific controller backplane revision. Consult the TDC3000 system hardware documentation to confirm if the rack bus supports live module insertion\/extraction without triggering process faults.\u003c\/p\u003e\n\u003cp\u003eQ: Are the RS-232 and RS-485 ports configurable via software?\u003c\/p\u003e\n\u003cp\u003eA: Port configuration, including baud rate and protocol parameters, is handled via the TDC3000 engineering station software. Physical wiring must align with the selected serial standard (RS-232 vs RS-485) as defined in the system setup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module into the designated rack slot, ensuring the backplane connector is fully seated to maintain robust electrical contact. The metal enclosure should be firmly bonded to the chassis to ensure mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the chassis ground lug to the cabinet earth bus using a low-impedance connection. This is mandatory for protecting the serial interface circuitry from electromagnetic interference (EMI) and transient voltage surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded, twisted-pair cabling for all serial runs. Maintain physical separation of at least 150 mm from high-voltage AC lines or motor power cables to prevent inductive noise injection into the RS-232\/RS-485 data lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47979519213758,"sku":"51304920-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-17_16-46-28_85af8834-282c-4ccc-ac7b-98a6790406ea.png?v=1783416108","url":"https:\/\/www.autooiltech.com\/products\/honeywell-51304920-100-serial-interface-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}