{"product_id":"honeywell-51304502-200-experion-series-dcs-cable-assembly","title":"Honeywell 51304502-200 Experion Series DCS Cable Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304502-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51304502\u003c\/strong\u003e Communication Cable Assembly, operates as a dedicated hardware component for high-integrity serial data interconnections within Experion PKS and TDC 3000 network architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304502-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1 m to 3 m length variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive interconnect assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell proprietary industrial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eExperion PKS, TDC 3000 DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Channel Isolation Properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Shielding Protection:\u003c\/strong\u003e High-density twisted-pair shielding prevents high-frequency electromagnetic interference (EMI) cross-talk from corrupting adjacent 4-20 mA current loops and digital fieldbus signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Noise Suppression:\u003c\/strong\u003e Braid and foil shielding layers isolate internal communication lines from high-voltage transients and local ground potential variations across system cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Impedance Signal Paths:\u003c\/strong\u003e Engineered with high-purity copper conductors to minimize attenuation and maintain waveform integrity across controller and I\/O module interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What connector standard is utilized on the 51304502-200 cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The assembly features Honeywell proprietary industrial connectors designed for direct plug-and-play mating with Experion PKS and TDC 3000 backplane receptacles.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 51304502-200 cable be hot-swapped during active DCS network transmission?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping network cable assemblies during active data transfer should be avoided, as momentary open circuits can cause communication timeouts or bad process values.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required to operate this cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: No, the cable assembly is a passive physical interconnect component and requires no auxiliary power input.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect cable connector pins and receptacle housing for mechanical alignment or debris prior to insertion.\u003c\/li\u003e\n\u003cli\u003eRoute the assembly through dedicated cabinet raceways, maintaining a minimum bend radius of 50 mm to protect internal conductors.\u003c\/li\u003e\n\u003cli\u003eKeep communication cable runs physically separated from AC power cables and high-voltage motor wiring by a minimum distance of 300 mm.\u003c\/li\u003e\n\u003cli\u003eEnsure connector retention latches or thumbscrews are fully engaged to establish solid shield continuity and prevent accidental disconnection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48493725253822,"sku":"51304502-200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/51201420-010_6b1db5c8-401a-4a3b-8db5-4924bf841650.png?v=1785917491","url":"https:\/\/www.autooiltech.com\/products\/honeywell-51304502-200-experion-series-dcs-cable-assembly","provider":"AutoOilTech Limited","version":"1.0","type":"link"}