{"product_id":"honeywell-51304453-150-analog-input-module","title":"Honeywell 51304453-150 Analog Input Module","description":"\u003cp\u003eConfigured for analog signal acquisition in Process Manager (PM) and High Performance Process Manager (HPM) architectures, the \u003cstrong\u003eHoneywell 51304453-150\u003c\/strong\u003e (\u003cstrong\u003e51304453\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e51304453:\u003c\/strong\u003e Base catalog number designating the High Level Analog Input (HLAI) \/ Smart Transmitter Interface (STI) processor card design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-150:\u003c\/strong\u003e Hardware specification code indicating factory conformal coating for corrosion protection in process environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (Packaging: 2.0 kg, Shipping: 3.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PM\/HPM card slot format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input \/ STI with Compression Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes (Conformally coated assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eNon-CE (Part N\/A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Channel Isolation Properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Shield Compatibility:\u003c\/strong\u003e Integrated low-pass filtering and shielded signal traces preserve signal integrity when interfacing with 4-20 mA current loops and smart field transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Noise Suppression \u0026amp; Conformal Coating:\u003c\/strong\u003e Onboard conformal coating protects high-density analog circuitry against atmospheric humidity and corrosive chemical gases, while internal galvanic isolation prevents common-mode noise propagation to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e Physical isolation circuits prevent ground potential differences and wiring shorts on individual input loops from causing measurement errors across adjacent analog channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What field device types interface with the 51304453-150 module?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to accept high-level analog signals (4-20 mA \/ 1-5 VDC) as well as smart field transmitter digital signals via compression terminal connections.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 51304453-150 module be replaced while the I\/O rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Online removal and insertion are supported provided associated process control loops are placed in a safe manual state and standard ESD protection procedures are followed.\u003c\/p\u003e\n\u003cp\u003eQ: How does the conformal coating on the -150 variant affect module durability?\u003c\/p\u003e\n\u003cp\u003eA: The specialized resin coating seals circuit board traces and surface-mount components, preventing galvanic corrosion in Class G3 industrial environments containing hydrogen sulfide or chlorine gases.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the module circuit board edge with the assigned card guides in the PM\/HPM I\/O rack and push firmly until backplane connections seat completely.\u003c\/li\u003e\n\u003cli\u003eSecure top and bottom faceplate retention screws to lock the module in place and establish frame ground continuity.\u003c\/li\u003e\n\u003cli\u003eRoute field input cables in dedicated cabinet wireways separate from high-voltage AC lines, keeping a minimum clearance of 300 mm.\u003c\/li\u003e\n\u003cli\u003eEnsure all instrument cable shield drain wires terminate at a single point on the cabinet chassis ground bar to mitigate ground loop interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48490685661374,"sku":"51304453-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/51304453-150_1200x1200_3f57e296-349f-45cc-aa4a-05d14a0a28a5.jpg?v=1785917724","url":"https:\/\/www.autooiltech.com\/products\/honeywell-51304453-150-analog-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}