{"product_id":"honeywell-51202971-111-i-o-link-cable","title":"Honeywell 51202971-111 I\/O Link Cable","description":"\u003ch1\u003eHoneywell 51202971-111 I\/O Link Cable\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHoneywell 51202971-111\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51202971\u003c\/strong\u003e I\/O Link 2 drop cable, operates as a dedicated extender for low-voltage signal distribution within Experion PKS Series 8 DCS architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e51202971-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eExperion PKS Series 8 \/ DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive cable, no active consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eExtends I\/O Link 2 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e12–24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumber of Drops\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e3 drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDistributed Control Systems, Experion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 51202971-111 cable is designed for \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e within Series 8 I\/O Link 2 networks. By maintaining separation between drop connections, the cable minimizes cross-talk and interference, ensuring stable low-voltage communication across distributed control modules. This isolation is critical in multi-drop configurations where simultaneous signals are routed through shared infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: How many drops does the cable support? A: The cable supports 3 drops for I\/O Link 2 extension.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Is shielding included for EMI\/RFI protection? A: Yes, the cable construction includes shielding suitable for industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the cable be used across redundant Series 8 architectures? A: Yes, it is compatible with redundant DCS configurations requiring isolated drop connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoute the cable along designated trays to avoid mechanical stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure shielding braid is grounded at a single point to reduce EMI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain bend radius within manufacturer’s specification to prevent conductor fatigue.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify drop connectors are fully seated before energizing the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLabel each drop connection for traceability in multi-node installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48491054497982,"sku":"51202971-111","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/honeywell-51202971-112-combo-i-o-link-cable-oycwsgvk5ui_1da8eb08-2129-4840-81fe-129532feb915.png?v=1759025305","url":"https:\/\/www.autooiltech.com\/products\/honeywell-51202971-111-i-o-link-cable","provider":"AutoOilTech Limited","version":"1.0","type":"link"}