{"product_id":"honeywell-51202306-915-foe-i-o-lim-protection-cable","title":"Honeywell 51202306-915 FOE I\/O LIM Protection Cable","description":"\u003cp\u003eConfigured for fiber-optic controller-to-network communication in Experion PKS platforms, the \u003cstrong\u003eHoneywell 51202306-915\u003c\/strong\u003e (\u003cstrong\u003e51202306-915\u003c\/strong\u003e FOE I\/O LIM Protection Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e51202306-915\u003c\/td\u003e\n\u003ctd\u003e1.5-Meter FOE I\/O LIM Protection Cable with ST Connectors\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Distributed Control Networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e51202306-...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eHoneywell High-Reliability Fiber-Optic Cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51202306-915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1.5 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Fiber-Optic Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eST fiber-optic connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLink between DCS modules and FOE network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 51202306-915 cable utilizes optical fiber transmission media to provide galvanic isolation between connected DCS nodes, eliminating ground loops and protecting internal control architecture from severe electromagnetic interference (EMI) in industrial environments. It maintains channel integrity across high-speed data links while supporting secure communication between Local Interface Modules and Fieldbus over Ethernet (FOE) networks. Furthermore, factory-terminated ST connectors maintain low optical insertion loss, preventing signal attenuation and preserving data packet fidelity during continuous process automation tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the physical length of the 51202306-915 fiber-optic protection cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable features a standardized length of 1.5 meters with factory-terminated ST connectors on both ends.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ST connectors on this cable be field-terminated if a different length is required?\u003c\/p\u003e\n\u003cp\u003eA: No, the assembly is factory-sealed and pre-terminated to ensure precise optical alignment and minimize signal loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all connected system nodes are powered down and locked out prior to handling or routing the 51202306-915 fiber-optic cable. Route the cable through dedicated conduit pathways, avoiding sharp bends that exceed the minimum bend radius specified for fiber-optic glass strands. Inspect and clean the ST connector ferrules with approved optical wipes before inserting them into port receptacles to prevent contamination and signal degradation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48222055235774,"sku":"51202306-915","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-16_12-13-19_40e7da7f-9b34-4f5e-bbf3-cb7aba1183f3.png?v=1785294618","url":"https:\/\/www.autooiltech.com\/products\/honeywell-51202306-915-foe-i-o-lim-protection-cable","provider":"AutoOilTech Limited","version":"1.0","type":"link"}