{"product_id":"honeywell-2mlp-dc42-dc-input-power-module","title":"Honeywell 2MLP‑DC42 DC‑Input Power Module","description":"\u003ch2\u003eHoneywell 2MLP‑DC42 DC‑Input Power Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 2MLP‑DC42\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2MLP‑DC42\u003c\/strong\u003e DC‑input power module, supplies regulated DC voltages for MasterLogic systems. It provides stable 5 VDC output with defined protection functions, inrush control, and relay signaling for RUN‑status indication.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e2MLP-DC42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Performance Indicators\u003c\/th\u003e\n\u003ctd\u003e24 VDC input, 80 A peak inrush, 60% efficiency, 5 VDC output at 6.0 A, over‑current\/over‑voltage protection, RUN relay output, LED voltage indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated input voltage:\u003c\/strong\u003e DC 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e 80 A peak or less\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 60% or more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput fuse:\u003c\/strong\u003e Built‑in, user non‑replaceable, UL slow‑blow type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllowed instantaneous interruption:\u003c\/strong\u003e 10 ms or shorter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Specifications (Output 1)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e DC 5 V (±2%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current:\u003c\/strong\u003e 6.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver‑current protection:\u003c\/strong\u003e 6.6 A or more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver‑voltage protection:\u003c\/strong\u003e 5.5 V ~ 6.5 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelay Output (RUN Contact)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e RUN contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated switching voltage\/current:\u003c\/strong\u003e DC 24 V, 0.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum switching load:\u003c\/strong\u003e DC 5 V, 1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage indicator:\u003c\/strong\u003e LED ON when output voltage is normal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Terminal Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable specification:\u003c\/strong\u003e 0.75 ~ 2 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressed terminal:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported terminal types:\u003c\/strong\u003e RAV 1.25‑3.5, RAV 2‑3.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support user‑replaceable fuses A: No. The fuse is built‑in and not user‑replaceable.\u003c\/p\u003e\n\u003cp\u003eQ: What happens during a brief input voltage interruption A: Interruptions of \u003cstrong\u003e10 ms or shorter\u003c\/strong\u003e are tolerated without output drop.\u003c\/p\u003e\n\u003cp\u003eQ: Is the RUN relay output suitable for external alarms A: Yes. It can drive 24 VDC, 0.5 A loads such as small relays or signal lamps.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eUse properly sized 0.75–2 mm² conductors and approved RAV terminals. Maintain separation between power wiring and low‑level signal cables. Ensure stable 24 VDC supply to avoid triggering over‑current or over‑voltage protection. Confirm LED indication before commissioning downstream modules.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48211852492990,"sku":"2MLP‑DC42","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/2MLP-AC23_b9c37551-11ec-4dc7-950e-8c874e61fbab.png?v=1784280722","url":"https:\/\/www.autooiltech.com\/products\/honeywell-2mlp-dc42-dc-input-power-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}