{"product_id":"honeywell-05701-a-0326-interface-analog-output-module","title":"Honeywell 05701-A-0326 Interface Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51405098-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51405098-100\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for physical LCN co-processor interface execution within Experion LCN \/ Local Control Network platforms. The hardware functions as an analog driver board with integrated digital data modulation, enabling point-to-point host connectivity across processing servers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51405098-100 (51405098100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs (0.16 kg net assembly mass profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard server slot form factor interface card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Continuous ambient panel boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via motherboard interface slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eLCNP4E GUS \/ Experion LCN Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Compatibility\u003c\/td\u003e\n\u003ctd\u003eDell Precision T5500 and newer processing workstations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Configuration\u003c\/td\u003e\n\u003ctd\u003eAnalog Output with HART protocol overlay capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Rating\u003c\/td\u003e\n\u003ctd\u003e0.46 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal loop rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer (Superseded by 51454493-126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Integration:\u003c\/strong\u003e The circuit board supports 4-20 mA analog output current control layered with HART loop protocol digital modulation. It allows bidirectional diagnostic commands and configuration variables to be superimposed over the primary analog signaling line without altering the base current loop value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Parameters:\u003c\/strong\u003e To maintain systemic signal resolution, the module topology incorporates high-potential galvanic channel-to-channel isolation. This physical separation prevents stray field ground currents, cross-talk, and localized voltage loops from traveling back through the host bus and disrupting core DCS processing memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this interface card support installation inside legacy computing platforms?\u003c\/p\u003e\n\u003cp\u003eA: The 51405098-100 hardware configuration is specifically designed to meet the electrical and mechanical bus constraints of the Dell Precision T5500 and newer station architectures. Legacy computing slots may feature incompatible backplane bus velocities or pin assignments that prevent initializing the LCN link.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 24 VDC loop current limited across the analog output channels?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates built-in overcurrent protection circuits that clamp individual channel loops at a maximum threshold of 0.46 A. If an external short circuit or wiring fault occurs in the field distribution network, the localized hardware protection isolates the affected line to prevent whole-board thermal damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Power down the host workstation before installation. Align the 51405098-100 card straight with the designated expansion chassis slot guide. Press firmly down along the top edge of the board until the gold-plated edge contacts seat fully into the motherboard receptacle, and secure the mechanical faceplate screw to lock the assembly against panel vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all external 24 VDC analog and HART communication loops inside dedicated low-voltage wiring trays, maintaining a distinct physical separation from high-current AC power cables. Connect the external cable braided shield directly to the cabinet enclosure copper earth bus to prevent incoming radio frequency or electromagnetic fields from corrupting the continuous data telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47901305798846,"sku":"05701-A-0326","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-01_15-04-22_f5ed9e47-2038-410b-8ef4-6baeacf5e921.png?v=1782894021","url":"https:\/\/www.autooiltech.com\/products\/honeywell-05701-a-0326-interface-analog-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}