{"product_id":"hima-himatrix-f2do1602-f2-do-16-02-safety-related-remote-i-o-module","title":"HIMA HIMATRIX F2DO1602 F2 DO 16 02 Safety-Related Remote I\/O Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eHIMA HIMatrix F2 DO1602\u003c\/strong\u003e is a safety-related remote I\/O module designed for use in distributed control systems (DCS). With 16 relay outputs featuring forcibly guided contacts, Ethernet connectivity, and TÜV-certified compliance up to SIL 3, it ensures reliable and safe switching operations in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e F2 DO1602\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e Safety-related remote I\/O output module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HIMA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC, –15%…+20% (safe insulation per IEC 61131-2)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input (Max):\u003c\/strong\u003e 0.6 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFuse (External):\u003c\/strong\u003e 10 A time-lag (T)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≥ 10 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Interfaces:\u003c\/strong\u003e 2 × RJ-45, 10\/100BaseT with integrated switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBack-up Battery:\u003c\/strong\u003e None\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0…+60 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40…+85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType of Protection:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 255 × 114 × 113 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Types:\u003c\/strong\u003e 2 safety relays with forcibly guided contacts + 1 standard relay per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 16 potential-free normally open contacts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Voltage:\u003c\/strong\u003e ≥ 5 V, ≤ 30 VAC \/ 60 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Current:\u003c\/strong\u003e ≥ 10 mA, ≤ 3 A (internally fused with 3.15 A, breaking capacity 100 A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Capacity (AC):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL: 30 VAC at 3 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV: max. 50 VA (cos φ ≥ 0.5), max. 90 VA (cos φ = 1) at 30 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Capacity (DC, induction-free):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL: 24 VDC at 1 A ohmic load\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV: up to 30 VDC: max. 90 W (3.5 A); up to 60 VDC: max. 24 W (0.4 A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eContact Material:\u003c\/strong\u003e Silver alloy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Time:\u003c\/strong\u003e ~30 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReset Time:\u003c\/strong\u003e ~10 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBounce Time:\u003c\/strong\u003e ~15 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Life:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMechanical: ≥ 3 × 10⁶ switching operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical: ≥ 2.5 × 10⁵ switching operations at ohmic full load\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCertifications \u0026amp; Standards:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCE EMC, ATEX Zone 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTÜV IEC 61508 up to SIL 3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61511:2004\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEN 954-1:1996 up to Cat. 4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL ANSI\/UL 508, NFPA 70, NFPA 79\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCSA C22.2 No.142, CSA C22.2 No.213\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFM Approvals Class I, Div.2, Groups A–D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 61508, EN 1127-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe\u003cstrong\u003e F2 DO1602\u003c\/strong\u003e is ideal for safety-critical automation in chemical plants, oil \u0026amp; gas facilities, and energy systems. It ensures reliable relay-based output switching with forcibly guided contacts, making it suitable for emergency shutdown systems and high-integrity safety applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many relay outputs does the module provide?\u003c\/strong\u003e A: It provides 16 potential-free normally open relay outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What certifications does it meet?\u003c\/strong\u003e A: TÜV SIL 3, ATEX Zone 2, UL, CSA, and FM approvals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e A: The module operates between 0 and 60 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":46500433887422,"sku":"F2DO1602","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/hima-himatrix-f2do801-safety-remote-output-module-keeczfzxrjt.png?v=1773735632","url":"https:\/\/www.autooiltech.com\/products\/hima-himatrix-f2do1602-f2-do-16-02-safety-related-remote-i-o-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}