{"product_id":"general-electric-is430ssuah1a-universal-analog-i-o-module","title":"General Electric IS430SSUAH1A Universal Analog I\/O Module","description":"\u003ch2\u003eGE IS430SSUAH1A Universal Analog I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi‑mode analog and discrete signal processing in Mark VIeS control networks, the \u003cstrong\u003eGE IS430SSUAH1A\u003c\/strong\u003e (\u003cstrong\u003eIS430SSUAH1A\u003c\/strong\u003e Universal Analog I\/O Module) provides direct electrical execution of simplex analog channels and mixed‑signal conversions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS430SSUAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e28 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VIeS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUniversal Analog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCommon Mode Rejection (AC)\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e60 dB at 60 Hz (+‑5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCommon Mode Rejection (DC)\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e80 dB (‑5 to +7 V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eField Wiring Gauge\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e24 AWG min, 12 AWG max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAnalog Channels\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSixteen simplex analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSupported Signal Types\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eThermocouple, voltage input, current input, current output, RTD, pulse accumulator, digital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAssociated Components\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS420YUAAS1A I\/O pack, IS410SUAAS1A terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecial Modes\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNAMUR digital inputs, externally‑wetted outputs, internally‑wetted outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licenses\u003c\/h3\u003e\n\u003cp\u003eAs part of the GE Mark VIeS platform, the IS430SSUAH1A aligns with deterministic backplane communication rules used across the system’s I\/O packs. The module’s firmware flash compatibility ensures that the IS420YUAAS1A pack and IS410SUAAS1A terminal board maintain synchronized configuration files. I\/O density scaling is achieved through the universal analog architecture, allowing mixed‑signal channels to coexist without altering backplane timing. Profinet‑style deterministic behavior is preserved through fixed‑cycle updates between the I\/O pack and controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IS430SSUAH1A support hot‑swap insertion?\u003c\/strong\u003e A: No. The module should not be inserted or removed under power due to mixed‑signal channel sensitivity and pack‑to‑terminal board alignment requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 16‑bit converter resolution affect signal processing?\u003c\/strong\u003e A: The 16‑bit analog‑to‑digital converter provides fine granularity for voltage, current, and RTD measurements, improving channel stability across simplex operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there restrictions on discrete output wiring?\u003c\/strong\u003e A: Yes. Externally‑wetted and internally‑wetted outputs must follow the terminal board’s isolation zones to prevent cross‑channel interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a DIN rail with full mechanical engagement to ensure stable pack‑to‑terminal board alignment.\u003c\/li\u003e\n\u003cli\u003eRoute thermocouple and RTD wiring separately from digital outputs to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity and ground shields at a single termination point to avoid ground‑loop interference.\u003c\/li\u003e\n\u003cli\u003eObserve polarity and wiring gauge limits (24–12 AWG) when connecting current and voltage channels.\u003c\/li\u003e\n\u003cli\u003eVerify NAMUR input wiring against the terminal board’s designated low‑energy zones.\u003c\/li\u003e\n\u003cli\u003eInspect LED indicators on the associated I\/O pack during commissioning to confirm channel initialization and communication status.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45440207585470,"sku":"IS430SSUAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is430snuah1a-i-o-module-pc2rbk3d0mw_30f2ec32-b9ed-4f5b-a06d-0e3081094d78.png?v=1759023975","url":"https:\/\/www.autooiltech.com\/products\/general-electric-is430ssuah1a-universal-analog-i-o-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}