{"product_id":"general-electric-is220psfdh1a-power-supply","title":"General Electric IS220PSFDH1A Power Supply","description":"\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS220PSFDH1A\u003c\/strong\u003e Power Supply supports EX2100 and Mark VI turbine control systems with stable 335 VDC output for flame detection. This module powers up to eight detectors through a TMR diode‑ORed configuration that maintains continuous operation even during multiple supply failures. Its rugged design ensures reliable performance in demanding turbine environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eFunctional \u003c\/span\u003e\u003cspan\u003eDesign\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS220PSFDH1A\u003c\/strong\u003e operates on a 28 VDC input range of 26.6–29.4 V and delivers a regulated 335 VDC output with a 5% tolerance. The unit includes soft‑start capability that limits inrush current to 550 mA and incorporates a 7 mA current limit for stable operation. Its 1700 VDC isolation improves system safety during high‑energy events.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThree diagnostic LEDs provide clear status visibility, while filtered input circuitry reduces electromagnetic interference. The conformal‑coated PCB enhances durability in harsh industrial environments and maintains the module’s A‑rated revision performance. The \u003cstrong\u003eIS220PSFDH1A\u003c\/strong\u003e mounts above the TRPG terminal board and connects through P1 and P2 connectors for straightforward installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eParameters\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eModel \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIS220PSFDH1A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePower \u003c\/span\u003e\u003cspan\u003eSupply\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEX2100 \u003c\/span\u003e\u003cspan\u003e\/ \u003c\/span\u003e\u003cspan\u003eMark VI\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12.8 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e8.2 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e6 cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBrand \u003c\/span\u003e\u003cspan\u003eNew\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eHS \u003c\/span\u003e\u003cspan\u003eCode\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMOQ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLead \u003c\/span\u003e\u003cspan\u003eTime\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIn \u003c\/span\u003e\u003cspan\u003eStock\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOutput \u003c\/span\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e335 VDC \u003c\/span\u003e\u003cspan\u003e(±5%)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eInput \u003c\/span\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e28 VDC \u003c\/span\u003e\u003cspan\u003e(26.6–29.4 V)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1700 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eInrush \u003c\/span\u003e\u003cspan\u003eCurrent \u003c\/span\u003e\u003cspan\u003eLimit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e550 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eCurrent \u003c\/span\u003e\u003cspan\u003eLimit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConvection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eThree \u003c\/span\u003e\u003cspan\u003eLED \u003c\/span\u003e\u003cspan\u003eindicators\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePCB \u003c\/span\u003e\u003cspan\u003eProtection\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFull \u003c\/span\u003e\u003cspan\u003econformal \u003c\/span\u003e\u003cspan\u003ecoating\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eAbove \u003c\/span\u003e\u003cspan\u003eTRPG \u003c\/span\u003e\u003cspan\u003eterminal \u003c\/span\u003e\u003cspan\u003eboard\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eP1 \u003c\/span\u003e\u003cspan\u003e(input), \u003c\/span\u003e\u003cspan\u003eP2 \u003c\/span\u003e\u003cspan\u003e(output)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eTMR \u003c\/span\u003e\u003cspan\u003ediode‑ORed \u003c\/span\u003e\u003cspan\u003econfiguration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eAdditional \u003c\/span\u003e\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eNotes\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIS220PSFDH1A\u003c\/strong\u003e supports up to eight flame detectors in turbine applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe design eliminates cooling fans through efficient convection cooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe module improves reliability in wind turbine and gas turbine systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOver‑voltage protection enhances long‑term operational safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan\u003eApplications \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS220PSFDH1A\u003c\/strong\u003e supports flame detection systems in gas turbines, steam turbines, and wind turbine controls. It integrates with EX2100 and Mark VI architectures that require stable high‑voltage output and redundant protection. Its compact structure fits tightly packed control cabinets used in power generation facilities.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45445139431614,"sku":"IS220PSFDH1A","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is220psfdh1a-power-supply-o2b3iji3ljn.png?v=1759044246","url":"https:\/\/www.autooiltech.com\/products\/general-electric-is220psfdh1a-power-supply","provider":"AutoOilTech Limited","version":"1.0","type":"link"}