{"product_id":"general-electric-is220ppros1b-emergency-turbine-protection-i-o-pack","title":"General Electric IS220PPROS1B Emergency Turbine Protection I\/O Pack","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e Emergency Turbine Protection I\/O Pack strengthens Mark VIe turbine control systems with independent backup protection for gas and steam turbines. This module executes emergency trip actions, monitors speed‑related parameters, and maintains stable operation across a wide −30 °C to +65 °C temperature range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eFunctional Design\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e operates on 24 VDC power and interfaces with TREG, TREL, TRES, and TREA terminal boards to perform emergency trip functions. When configured in triple modular redundant (TMR) mode, three packs provide hardware‑based overspeed, acceleration, and deceleration protection. The module includes DC‑37 pin connectors for trip‑board communication and dual Ethernet IONet ports for network integration.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eKey Parameters\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eModel \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIS220PPROS1B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEmergency \u003c\/span\u003e\u003cspan\u003eTurbine \u003c\/span\u003e\u003cspan\u003eProtection \u003c\/span\u003e\u003cspan\u003eI\/O \u003c\/span\u003e\u003cspan\u003ePack\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.38 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e6 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e12.8 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e8.2 cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBrand \u003c\/span\u003e\u003cspan\u003eNew\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eHS \u003c\/span\u003e\u003cspan\u003eCode\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMOQ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLead \u003c\/span\u003e\u003cspan\u003eTime\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIn \u003c\/span\u003e\u003cspan\u003eStock\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eDual \u003c\/span\u003e\u003cspan\u003eEthernet \u003c\/span\u003e\u003cspan\u003eIONet \u003c\/span\u003e\u003cspan\u003eports\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePower \u003c\/span\u003e\u003cspan\u003eInput\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e−30 °C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+65 °C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eDC‑37 \u003c\/span\u003e\u003cspan\u003epin \u003c\/span\u003e\u003cspan\u003econnectors\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eInstallation \u003c\/span\u003e\u003cspan\u003eModes\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eDirect‑mount \u003c\/span\u003e\u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003ecable‑connected\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eTMR‑ready \u003c\/span\u003e\u003cspan\u003earchitecture\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eAutonomous \u003c\/span\u003e\u003cspan\u003efault \u003c\/span\u003e\u003cspan\u003edetection\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eToolboxST® \u003c\/span\u003e\u003cspan\u003econfiguration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAdditional Technical Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e supports emergency trip execution independent of primary controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDual‑network operation enables simultaneous monitoring of R and S controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSoft‑start circuitry protects internal components during activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe rugged design meets GEH‑6721L specifications for turbine‑protection hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications and Compatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e supports gas turbines, steam turbines, and combined‑cycle plants that require reliable emergency trip capability. It integrates with Mark VIe Speedtronic architectures and connects directly to GE emergency trip boards for high‑reliability protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003ch3\u003eWhy Industries Choose the \u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIt enhances turbine safety through independent, hardware‑based protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIt supports TMR architectures for fault‑tolerant operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIt withstands harsh environments with wide‑range temperature capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIt simplifies installation with flexible mounting and clear interface options.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45445150769342,"sku":"IS220PPROS1B","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is220ppros1b-emergency-turbine-protection-i-o-pack-ou1td1r1jlp.png?v=1759044606","url":"https:\/\/www.autooiltech.com\/products\/general-electric-is220ppros1b-emergency-turbine-protection-i-o-pack","provider":"AutoOilTech Limited","version":"1.0","type":"link"}