{"product_id":"general-electric-is200vturh1baa-mk6-gas-tmr-pk-turbine-card","title":"General Electric IS200VTURH1BAA MK6 Gas Tmr Pk Turbine Card","description":"\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS200VTURH1BAA\u003c\/strong\u003e MK6 Gas TMR PK Turbine Card supports Mark VIe turbine control systems with precise overspeed protection, flame detection, and shaft‑voltage monitoring. This board strengthens gas and steam turbine safety through fast trip response and accurate pulse‑rate processing. Its rugged construction ensures stable operation in demanding power‑generation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eFunctional \u003c\/span\u003e\u003cspan\u003eDesign\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200VTURH1BAA\u003c\/strong\u003e manages three overspeed trip relays in simplex systems and nine magnetic relays in TMR architectures. It processes signals from four passive pulse‑rate devices across a 2 Hz–20 kHz range with 0.05% accuracy, enabling precise turbine speed monitoring. The board also supports eight Geiger‑Mueller flame detectors used in gas turbine applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIS200VTURH1BAA\u003c\/strong\u003e integrates with TRPG terminal boards to activate emergency solenoids and supports automatic generator synchronization and breaker control. Its front panel includes RUN, FAIL, and STATUS LEDs, along with a D‑shell connector for system interfacing. The board detects speeds as low as 2 RPM with a 27 mV sensitivity threshold, ensuring reliable low‑speed monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eParameters\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eModel \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIS200VTURH1BAA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eMK6 \u003c\/span\u003e\u003cspan\u003eGas \u003c\/span\u003e\u003cspan\u003eTMR \u003c\/span\u003e\u003cspan\u003ePK \u003c\/span\u003e\u003cspan\u003eTurbine \u003c\/span\u003e\u003cspan\u003eCard\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eGeneral \u003c\/span\u003e\u003cspan\u003eElectric\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2.1 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e18.6 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e26.1 cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBrand \u003c\/span\u003e\u003cspan\u003eNew\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eHS \u003c\/span\u003e\u003cspan\u003eCode\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMOQ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLead \u003c\/span\u003e\u003cspan\u003eTime\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIn \u003c\/span\u003e\u003cspan\u003eStock\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEthernet \u003c\/span\u003e\u003cspan\u003erouter \u003c\/span\u003e\u003cspan\u003einterface\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePulse \u003c\/span\u003e\u003cspan\u003eInput \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Hz–20 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eFlame \u003c\/span\u003e\u003cspan\u003eDetectors\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSupports \u003c\/span\u003e\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003eGM \u003c\/span\u003e\u003cspan\u003edetectors\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelays\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003e(simplex), \u003c\/span\u003e\u003cspan\u003e9 \u003c\/span\u003e\u003cspan\u003e(TMR)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSpeed \u003c\/span\u003e\u003cspan\u003eSensitivity\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2 RPM \u003c\/span\u003e\u003cspan\u003e(27 mV)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePCB \u003c\/span\u003e\u003cspan\u003eProtection\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFull \u003c\/span\u003e\u003cspan\u003econformal \u003c\/span\u003e\u003cspan\u003ecoating\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eVME \u003c\/span\u003e\u003cspan\u003erack \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003ecaptive \u003c\/span\u003e\u003cspan\u003escrews\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eAdditional \u003c\/span\u003e\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eNotes\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIS200VTURH1BAA\u003c\/strong\u003e supports overspeed trip logic for gas and steam turbines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe board integrates with TRPG terminal boards for emergency solenoid activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic LEDs improve visibility during commissioning and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe revision structure (B\/A\/A) maintains backward compatibility with earlier Mark VI hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan\u003eApplications \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS200VTURH1BAA\u003c\/strong\u003e supports turbine protection systems in power plants that require precise overspeed detection, flame monitoring, and shaft‑voltage supervision. It integrates with Mark VI and Mark VIe Speedtronic architectures used in gas turbines, steam turbines, and auxiliary protection panels.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electricneral Electric","offers":[{"title":"Default Title","offer_id":45445140775102,"sku":"IS200VTURH1BAA","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200vturh1baa-mk6-gas-tmr-pk-turbine-card-y4vn3r1xr1d.png?v=1759044289","url":"https:\/\/www.autooiltech.com\/products\/general-electric-is200vturh1baa-mk6-gas-tmr-pk-turbine-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}