{"product_id":"general-electric-is200tvbah2acc-vibration-input-terminal-board","title":"General Electric IS200TVBAH2ACC Vibration Input Terminal Board","description":"\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS200TVBAH2ACC\u003c\/strong\u003e Vibration Input Terminal Board supports Mark VIe turbine control systems with precise vibration‑signal conditioning and robust environmental protection. This board strengthens gas and steam turbine monitoring through accurate analog processing and stable operation in harsh industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eFunctional \u003c\/span\u003e\u003cspan\u003eDesign\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200TVBAH2ACC\u003c\/strong\u003e provides 16‑channel analog input conditioning with ±0.1% measurement accuracy, enabling precise detection of mechanical vibration trends. Its circuitry processes signals from seismic sensors and proximity probes used in turbine protection systems. The conformal‑coated PCB resists moisture, dust, and chemical contaminants, ensuring long‑term reliability in power‑plant environments.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eParameters\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eModel \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIS200TVBAH2ACC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eVibration \u003c\/span\u003e\u003cspan\u003eInput \u003c\/span\u003e\u003cspan\u003eTerminal \u003c\/span\u003e\u003cspan\u003eBoard\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eGeneral \u003c\/span\u003e\u003cspan\u003eElectric\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.42 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e33 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e17.8 cm \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e5.5 cm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCondition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBrand \u003c\/span\u003e\u003cspan\u003eNew\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eHS \u003c\/span\u003e\u003cspan\u003eCode\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMOQ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLead \u003c\/span\u003e\u003cspan\u003eTime\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIn \u003c\/span\u003e\u003cspan\u003eStock\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEthernet \u003c\/span\u003e\u003cspan\u003erouter \u003c\/span\u003e\u003cspan\u003einterface\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eAnalog \u003c\/span\u003e\u003cspan\u003eChannels\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e16‑channel \u003c\/span\u003e\u003cspan\u003evibration \u003c\/span\u003e\u003cspan\u003einputs\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eOperating \u003c\/span\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e−40 °C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e+70 °C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePCB \u003c\/span\u003e\u003cspan\u003eProtection\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFull \u003c\/span\u003e\u003cspan\u003econformal \u003c\/span\u003e\u003cspan\u003ecoating\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArchitecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eTMR‑ready \u003c\/span\u003e\u003cspan\u003evibration \u003c\/span\u003e\u003cspan\u003emonitoring\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShielding\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEMI‑protected \u003c\/span\u003e\u003cspan\u003ecircuitry\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIEEE C37.90 \u003c\/span\u003e\u003cspan\u003esurge‑withstand\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eAdditional \u003c\/span\u003e\u003cspan\u003eTechnical \u003c\/span\u003e\u003cspan\u003eNotes\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIS200TVBAH2ACC\u003c\/strong\u003e processes seismic and proximity‑probe signals for turbine protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic calibration improves long‑term measurement stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEMI shielding enhances accuracy in electrically noisy turbine environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe board integrates with Mark VIe distributed I\/O for real‑time diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan\u003eApplications \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe General Electric \u003cstrong\u003eIS200TVBAH2ACC\u003c\/strong\u003e supports gas turbines, steam turbines, and combined‑cycle plants that require precise vibration monitoring. It integrates with Mark VIe Speedtronic architectures and suits mission‑critical power‑generation environments that demand high‑reliability machinery protection.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electricneral Electric","offers":[{"title":"Default Title","offer_id":45445150245054,"sku":"IS200TVBAH2ACC","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200tvbah2acc-vibration-input-terminal-board-x3jactglz3c.png?v=1759044585","url":"https:\/\/www.autooiltech.com\/products\/general-electric-is200tvbah2acc-vibration-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}