{"product_id":"general-electric-ds200imcpg1ccb-power-supply-interface-board","title":"General Electric DS200IMCPG1CCB Power Supply Interface Board","description":"\u003cp\u003eConfigured for turbine control management in Mark V Speedtronic systems, the \u003cstrong\u003eGeneral Electric DS200IMCPG1CCB\u003c\/strong\u003e (\u003cstrong\u003eDS200IMCPG1CCB\u003c\/strong\u003e Power Supply Interface Board) provides direct physical execution of power distribution and signal interface tasks across automated drive assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eMark V Series assembly type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMCP\u003c\/td\u003e\n\u003ctd\u003eFunctional product acronym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eGroup 1 Mark V Series product grouping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003ePrimary functional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSecondary functional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eArtwork configuration revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200IMCPG1CCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eDomestic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The board facilitates high-speed data exchange with the SDCC drive control board via the 1PL input connector, supporting the deterministic timing required for turbine control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e While the board operates within the proprietary Mark V bus architecture, the interface is designed to maintain signal synchronization necessary for integration into broader deterministic industrial control environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The board features a dense population of integrated circuits and discrete components to maximize signal interface capacity within the limited footprint of the Mark V turbine control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The hardware revision history (C-C-B) ensures compatibility with specific Mark V firmware versions, allowing for standardized operational parameters across the turbine drive control assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the mounting holes on the PCB protected against electrical discharge?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board features factory-drilled installation holes ringed with insulating material to prevent high-voltage surface potentials from reaching the mounting hardware or cabinet chassis.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended procedure for replacing board-level fuses?\u003c\/p\u003e\n\u003cp\u003eA: Before replacing any fuse, verify that the board is fully de-energized and tested for zero voltage. Fuses must be replaced with identical ratings to maintain circuit protection integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board using the pre-drilled edge and corner holes. Ensure that the mounting hardware does not compromise the insulating rings around the drill holes to maintain dielectric isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the cabinet chassis provides a solid common ground reference for the board. The interface relies on a low-impedance ground path to suppress electromagnetic interference and ensure the stability of the voltage-limiting components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the board to the SDCC drive control unit using the specified cable interface at the 1PL connector. Route interface cables away from high-power cabling to prevent induced noise on the sensitive resistor network arrays and integrated circuits. Ensure all stab-on connectors are fully seated to avoid intermittent connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48160684474558,"sku":"DS200IMCPG1CCB","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-13_15-22-25__1_ac689de5-c79d-4934-9fbc-747eeb9f20a5.png?v=1784001424","url":"https:\/\/www.autooiltech.com\/products\/general-electric-ds200imcpg1ccb-power-supply-interface-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}