{"product_id":"ge-multilin-ur-6hh-digital-i-o-module","title":"GE Multilin UR-6HH Digital I\/O Module","description":"\u003ch2\u003eGE Multilin UR 6HH Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR 6HH\u003c\/strong\u003e is a high‑density Digital I\/O module designed for Universal Relay (UR) systems. It provides a mix of Form‑A, Form‑C, and Fast Form‑C contact outputs and digital inputs, enabling UR relays to interface with switches, pushbuttons, fans, valves, lights, and other auxiliary equipment. The UR‑6HH is part of the flexible modular architecture of the UR family, allowing users to scale contact I\/O capacity based on system requirements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003eUR‑6HH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eOntario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e6 in × 7 in × 1.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSoftware Support\u003c\/th\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Types\u003c\/th\u003e\n\u003ctd\u003eForm‑A, Form‑C, Fast Form‑C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutputs\u003c\/th\u003e\n\u003ctd\u003eSix Form‑A outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs\u003c\/th\u003e\n\u003ctd\u003eDigital inputs (wet or dry contact compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eUR modular chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR‑6HH\u003c\/strong\u003e module expands the digital I\/O capability of UR relays, supporting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 96 contact inputs\u003c\/strong\u003e (depending on relay configuration)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUp to 64 contact outputs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Form‑A outputs\u003c\/strong\u003e (specific to the UR‑6HH variant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDigital inputs may be \u003cstrong\u003ewet (active)\u003c\/strong\u003e or \u003cstrong\u003edry (passive)\u003c\/strong\u003e contacts:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry contacts\u003c\/strong\u003e provide galvanic isolation between devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWet contacts\u003c\/strong\u003e do not provide isolation and rely on external voltage sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module integrates seamlessly with GE Multilin’s \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software suite, enabling configuration, monitoring, and diagnostics through Viewpoint Monitoring and Viewpoint Maintenance tools.\u003c\/p\u003e\n\u003ch3\u003ePlacement Within a UR Relay\u003c\/h3\u003e\n\u003cp\u003eThe location of the UR‑6HH module inside a relay depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003erelay model\u003c\/strong\u003e (e.g., B30, C30, T60, L60, etc.)\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eorder code\u003c\/strong\u003e of the relay\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003enumber of digital I\/O modules\u003c\/strong\u003e installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExample: In a B30 relay order code such as:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eB30‑H00‑HCL‑F8H‑H6H‑L8H‑N6A‑S8H‑U6H\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe segments \u003cstrong\u003eH6H\u003c\/strong\u003e and \u003cstrong\u003eU6H\u003c\/strong\u003e indicate digital I\/O modules. Their physical placement corresponds to the slot positions defined by the relay’s modular chassis layout.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where is the UR‑6HH located inside a UR relay?\u003c\/strong\u003e A: Placement varies by relay type and order code. Digital I\/O modules appear in specific slot positions indicated by two‑character codes (e.g., 6H, 6A) within the relay’s model number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Form‑A outputs does the UR‑6HH provide?\u003c\/strong\u003e A: The UR‑6HH includes \u003cstrong\u003esix Form‑A outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of digital contacts does the module support?\u003c\/strong\u003e A: Form‑A, Form‑C, and Fast Form‑C outputs, plus wet and dry digital inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is fully seated in the UR chassis to maintain reliable contact‑signal timing.\u003c\/li\u003e\n\u003cli\u003eSeparate digital I\/O wiring from CT\/VT circuits to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eUse shielded wiring for wet contacts and terminate shields at a single point.\u003c\/li\u003e\n\u003cli\u003eConfirm contact type requirements (Form‑A vs. Form‑C vs. Fast Form‑C) before installation.\u003c\/li\u003e\n\u003cli\u003eVerify connector engagement before energizing the relay.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48161100267710,"sku":"UR6HH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-06_10-09-30.png?v=1783304777","url":"https:\/\/www.autooiltech.com\/products\/ge-multilin-ur-6hh-digital-i-o-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}