{"product_id":"ge-is220phrah1b-enabled-analog-i-o-module","title":"GE IS220PHRAH1B Enabled Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS220PHRAH1B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS220PHRAH1B\u003c\/strong\u003e HART Enabled Analog I\/O Module, operates as a dedicated hardware component for analog signal acquisition and loop control translation within Mark VIe networks. The module interfaces dual RJ45 Ethernet networks with a separate multi-channel terminal board via a high-density DC-62 pin connector.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PHRAH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe I\/O pack component mass profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.25 in x 1.65 in x 4.78 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C (Standard control room cabinet limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven via standard 3-pin external DC power input connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e10 Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Analog Outputs (4-20 mA current loops)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e14-bit digital-to-analog converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Scan Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Load\u003c\/td\u003e\n\u003ctd\u003e800 Ohm for 4-20 mA output loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Technology\u003c\/td\u003e\n\u003ctd\u003eSurface-mount technology (SMD) on dual-board stack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Industrial Control and Deterministic Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Multi-Channel Routing:\u003c\/strong\u003e The component aggregates a total of 12 internal processing channels inside a localized distributed block. The hardware architecture scales localized node layouts by mounting directly to terminal boards, parsing up to 10 distinct sensor transmitter wires alongside 2 independent actuator field outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility and Network Connectivity:\u003c\/strong\u003e The dual-board design separates general operating logic from target interface loops. The primary processor board maintains common system firmware lines across the dual redundant RJ45 Ethernet communication channels, keeping synchronization speeds constant while the secondary acquisition board sequences raw converter registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle signal conditioning for different current loop input types?\u003c\/p\u003e\n\u003cp\u003eA: The hardware package senses voltage drops across precision load termination resistors situated directly on the corresponding terminal board. The input circuitry reads these scaling voltage potentials, converting the values through its 16-bit registers to support 2-wire, 3-wire, or 4-wire hardware options.\u003c\/p\u003e\n\u003cp\u003eQ: Is it possible to isolate or hot-swap the IS220PHRAH1B module while the processing networks are running?\u003c\/p\u003e\n\u003cp\u003eA: Yes, if deployed inside a redundant dual or triple modular network setup. The dual RJ45 control paths allow a single module to be separated from its DC-62 pin base terminal while tracking modules absorb the control frame updates without fault timeouts.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47897029443774,"sku":"IS220PHRAH1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-30_10-35-43_cfdeeea9-018d-43e3-86cf-d358a3240f98.png?v=1782787015","url":"https:\/\/www.autooiltech.com\/products\/ge-is220phrah1b-enabled-analog-i-o-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}