{"product_id":"ge-is220pdoah1b-is230snrlh2a-discrete-output-module-1","title":"GE IS220PDOAH1B（IS230SNRLH2A）Discrete Output Module","description":"\u003cp\u003eConfigured for discrete output execution in Mark VIe and Mark VIeS turbine control systems, the \u003cstrong\u003eGeneral Electric IS220PDOAH1B(IS230SNRLH2A)\u003c\/strong\u003e (\u003cstrong\u003eIS220PDOAH1B(IS230SNRLH2A)\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog designation \u003cstrong\u003eIS220PDOAH1B(IS230SNRLH2A)\u003c\/strong\u003e defines a specific hardware revision and I\/O pack pairing. The base identifier \u003cstrong\u003eIS220PDOAH1B\u003c\/strong\u003e denotes the discrete output module assembly, while the parenthetical \u003cstrong\u003eIS230SNRLH2A\u003c\/strong\u003e designates the integrated processor and communication I\/O pack architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PDOAH1B(IS230SNRLH2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e263 mm x 58 mm x 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDual 28 VDC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24-28 VDC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1 A per channel (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module executes high-performance control tasks across industrial networks while maintaining rigid timing characteristics. Key operational behaviors include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupporting deterministic network communication paths across dual 10\/100 Mbps Ethernet (RJ45) ports to maintain synchronized command execution for solenoids, motor starters, and valves.\u003c\/li\u003e\n\u003cli\u003eManaging I\/O density scaling efficiently through a compact, rack-mounted modular architecture equipped with real-time diagnostic capabilities.\u003c\/li\u003e\n\u003cli\u003eProcessing discrete commands with a response time of \u0026lt;10 ms while providing signal isolation of 500 VDC across channel-to-channel and ground boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply architecture does the IS220PDOAH1B(IS230SNRLH2A) utilize for operational redundancy?\u003c\/p\u003e\n\u003cp\u003eA: It features dual 28 VDC power inputs equipped with automatic failover to ensure continuous control power availability.\u003c\/p\u003e\n\u003cp\u003eQ: Does this discrete output module support hot-swapping within the Mark VIe control rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The modular rack-mounted design supports unpowered or system-managed hot insertion and extraction when implemented within designated redundant controller topologies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the system rack power supply is completely de-energized and locked out (LOTO) prior to sliding the module into the Mark VIe I\/O rack.\u003c\/li\u003e\n\u003cli\u003eVerify proper mechanical alignment along the rack guide rails before securing the unit (dimensions 263 mm x 58 mm x 28 mm) to maintain backplane integrity.\u003c\/li\u003e\n\u003cli\u003eTerminate dual 28 VDC power feeds and field discrete output wiring securely, ensuring proper signal shielding and grounding up to the 500 VDC isolation rating.\u003c\/li\u003e\n\u003cli\u003eEstablish dual 10\/100 Mbps Ethernet (RJ45) network connections and verify LED diagnostic indicators prior to restoring system power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48215747231934,"sku":"IS220PDOAH1B(IS230SNRLH2A)","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-02_11-15-33_063b4621-6bb2-4e2c-95a0-ef1a652354d4.png?v=1785232974","url":"https:\/\/www.autooiltech.com\/products\/ge-is220pdoah1b-is230snrlh2a-discrete-output-module-1","provider":"AutoOilTech Limited","version":"1.0","type":"link"}