{"product_id":"ge-is215ucveh2ae-mark-vi-vme-controller-card","title":"GE IS215UCVEH2AE Mark VI VME Controller Card","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS215UCVEH2AE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS215UCVEH2AE\u003c\/strong\u003e VME Controller Card, operates as a dedicated hardware component for real-time processing and turbine logic execution within Mark VI Gas Turbine Control Systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS215UCVEH2AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 lbs (0.13 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Single-Slot VME Bus Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via VME backplane internal power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet Input\/Output Network Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eVMEbus Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics \u0026amp; Clock\u003c\/td\u003e\n\u003ctd\u003eIntegrated Real-Time Clock (RTC), Status LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS215UCVEH2AE\u003c\/strong\u003e controller card utilizes a high-performance onboard processor to manage real-time speed, load, and sequence control for gas turbine operation. Featuring two dual Ethernet network ports, the board supports deterministic network communication across control nodes while interfacing directly with the VME backplane rack. Onboard firmware flash compatibility ensures synchronized code execution across redundant controller configurations, while integrated status LEDs provide real-time visual diagnostics for processor health and network activity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What network interface configurations are available on the IS215UCVEH2AE VME card?\u003c\/p\u003e\n\u003cp\u003eA: The board is equipped with two dedicated Ethernet I\/O ports designed to handle deterministic controller-to-controller and I\/O network communication within the Mark VI system.\u003c\/p\u003e\n\u003cp\u003eQ: How is the IS215UCVEH2AE controller card powered and grounded inside the rack?\u003c\/p\u003e\n\u003cp\u003eA: Electrical power is drawn directly from the backplane power supply when seated in the Mark VI VME chassis, with grounding established through the backplane connectors and front panel retaining screws.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS215UCVEH2AE card support live backplane insertion or hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No, power to the VME rack must be completely de-energized prior to installing or removing the card to prevent electrical transients and processor corruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the Mark VI control enclosure and confirm that the VME rack backplane is completely de-energized.\u003c\/li\u003e\n\u003cli\u003ePut on an anti-static wrist strap attached to an unpainted chassis ground point before touching the card assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the IS215UCVEH2AE board edges with the designated VME slot card guides inside the rack chassis.\u003c\/li\u003e\n\u003cli\u003eSlide the card smoothly into the slot until rear multi-pin connectors align, then press firmly until the board seats into the backplane.\u003c\/li\u003e\n\u003cli\u003eSecure the top and bottom front panel retaining screws, attach Ethernet cables to the I\/O network ports, and restore power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":48749999161534,"sku":"IS215UCVEH2AE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS215UCVEH2AE_1200x1200_2ac9a2f1-b3e0-44a6-999d-1e26ec31057a.jpg?v=1787023604","url":"https:\/\/www.autooiltech.com\/products\/ge-is215ucveh2ae-mark-vi-vme-controller-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}