{"product_id":"ge-is200wemah1awa-exciter-pt-ct-terminal-board","title":"GE IS200WEMAH1AWA Exciter PT\/CT Terminal Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200WEMAH1AWA\u003c\/strong\u003e Exciter PT\/CT Terminal Board provides transformer‑isolated PT\/CT signal termination and routing for EX2100\/Mark VIe excitation‑control measurement systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: IS200WEMAH1AWA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: EX2100 \/ Mark VIe Excitation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e: Exciter PT\/CT Terminal Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePT Inputs\u003c\/strong\u003e: Three‑phase generator PT voltage inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCT Inputs\u003c\/strong\u003e: 1 A \/ 5 A generator CT current inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Transformer‑isolated PT\/CT measurement channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 115 V rms PT input at 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e: Routed to EMIO measurement boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Input\u003c\/strong\u003e: One selectable voltage or 4–20 mA current input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eJumpers\u003c\/strong\u003e: Input‑type selection jumpers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: Removable PT block; fixed CT blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTest Points\u003c\/strong\u003e: Secondary‑side transformer test points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Excitation‑system voltage and current measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransformer Isolation\u003c\/strong\u003e: Provides safe, isolated PT\/CT measurement paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePT\/CT Versatility\u003c\/strong\u003e: Supports standard generator PT and CT inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Input Support\u003c\/strong\u003e: Accepts voltage or 4–20 mA current signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance‑Friendly Design\u003c\/strong\u003e: Removable PT block; fixed CT blocks prevent open‑circuit hazards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDirect EMIO Integration\u003c\/strong\u003e: Clean routing to EMIO boards for excitation control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTest Points\u003c\/strong\u003e: Eight transformer‑secondary test points for commissioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Reliability\u003c\/strong\u003e: Designed for critical generator‑excitation measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_does_IS200WEMAH1AWA_do\u003c\/strong\u003e: It terminates and isolates generator PT\/CT signals for EX2100\/Mark VIe excitation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_support_CT_and_PT\u003c\/strong\u003e: Yes, it supports three‑phase PT and 1 A\/5 A CT inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_there_an_analog_input\u003c\/strong\u003e: Yes, one selectable voltage or 4–20 mA input.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhy_are_CT_blocks_fixed\u003c\/strong\u003e: To prevent dangerous CT open‑circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhere_are_signals_routed\u003c\/strong\u003e: To EMIO measurement boards in the excitation controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48161040662718,"sku":"IS200WEMAH1AWA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200wetbh1a-top-box-b-module-r02wrjfye0z.png?v=1759047133","url":"https:\/\/www.autooiltech.com\/products\/ge-is200wemah1awa-exciter-pt-ct-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}