{"product_id":"ge-is200tvbah2a-vibration-input-terminal-board","title":"GE IS200TVBAH2A Vibration Input Terminal Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GE \u003cstrong\u003eIS200TVBAH2A\u003c\/strong\u003e Vibration Input Terminal Board provides passive termination, signal routing, and conditioning paths for vibration probes used with Mark VI\/VIe monitoring modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: IS200TVBAH2A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: Mark VI \/ Mark VIe\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e: Vibration Input Terminal Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProbe Compatibility\u003c\/strong\u003e: Eddy‑current, seismic, velocity, accelerometer probes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: Multi‑channel vibration signal termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e: Low‑noise analog vibration and phase signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring Method\u003c\/strong\u003e: Screw‑type terminal blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Single‑end shield bonding for noise reduction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRouting\u003c\/strong\u003e: Direct feed to VVIB\/VVIM acquisition modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eJumpers\u003c\/strong\u003e: Channel configuration jumpers for probe type selection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Panel‑mounted inside Mark VI\/VIe cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Turbine vibration monitoring and rotor‑dynamic analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti‑Probe Support\u003c\/strong\u003e: Accepts displacement, velocity, seismic, and accelerometer probes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLow‑Noise Routing\u003c\/strong\u003e: Preserves analog signal integrity for vibration analysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConfigurable Channels\u003c\/strong\u003e: Jumpers allow probe‑type selection per channel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShield Management\u003c\/strong\u003e: Single‑end bonding reduces induced noise\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDirect VVIB\/VVIM Integration\u003c\/strong\u003e: Optimized for GE vibration acquisition modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: Robust PCB and terminals for harsh turbine environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_does_IS200TVBAH2A_do\u003c\/strong\u003e: It terminates and routes vibration probe signals to GE VVIB\/VVIM modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhich_probes_are_supported\u003c\/strong\u003e: Eddy‑current, seismic, velocity, and accelerometer probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_have_jumpers\u003c\/strong\u003e: Yes, jumpers configure channels for different probe types.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow_should_shields_be_wired\u003c\/strong\u003e: Bond shields at one end only to reduce noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhere_is_it_installed\u003c\/strong\u003e: Inside Mark VI\/VIe turbine‑control cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electricneral Electric","offers":[{"title":"Default Title","offer_id":48160962838718,"sku":"IS200TVBAH2A","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200tvbah2acc-vibration-input-terminal-board-x3jactglz3c.png?v=1759044585","url":"https:\/\/www.autooiltech.com\/products\/ge-is200tvbah2a-vibration-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}