{"product_id":"ge-is200tcash1acb-terminal-board","title":"GE IS200TCASH1ACB Terminal Board","description":"\u003ch2\u003eGE IS200TCASH1ACB Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TCASH1ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TCASH1ACB\u003c\/strong\u003e terminal board, operates as a dedicated routing interface for bulk control‑power distribution and analog\/digital signal transfer within Mark VIe turbine control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eIS200TCASH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e33.02 cm × 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e30 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive terminal board; negligible draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eTerminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs\u003c\/th\u003e\n\u003ctd\u003e25 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutputs\u003c\/th\u003e\n\u003ctd\u003e4–20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog Output Current\u003c\/th\u003e\n\u003ctd\u003e0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Lead Resistance\u003c\/th\u003e\n\u003ctd\u003e15 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnology\u003c\/th\u003e\n\u003ctd\u003eSurface‑mount PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBackplane\/Board Interface\u003c\/th\u003e\n\u003ctd\u003eP1\/P2 68‑pin connectors to TCAT; P4\/P5 power routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eTerminal Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManual\u003c\/th\u003e\n\u003ctd\u003eGEH‑6721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eWithin Mark VIe architectures, TCAS‑series terminal boards align with GE backplane bus communication velocity limits and deterministic Profinet \/ EtherNet\/IP timing. Although TCAS itself is passive, its routing paths support fixed‑cycle analog sampling and output updates when paired with BCAA\/BCAB processing boards. Firmware flash compatibility ensures that ControlST updates do not disturb established scaling tables or excitation‑power routing. I\/O density scaling remains stable across simplex and redundant pack configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200TCASH1ACB be hot‑swapped? A: No. Terminal boards are not designed for live hot‑swap. Removal or insertion should occur only when the associated rack segment is de‑energized to avoid transient loading on the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How does TCAS interact with BCAA and BCAB boards? A: TCAS provides routed analog and digital signals through internal connectors, delivering them directly to BCAA\/BCAB analog‑processing boards for conditioning.\u003c\/p\u003e\n\u003cp\u003eQ: Does excitation‑voltage routing affect analog output scaling? A: No. Excitation voltage is routed for contact and transmitter power. Analog output scaling is determined by the processing boards, not the terminal board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain shield continuity at terminal blocks to reduce induced noise from adjacent high‑current conductors.\u003c\/li\u003e\n\u003cli\u003eVerify correct landing of 24 VDC excitation and return conductors before energizing the panel.\u003c\/li\u003e\n\u003cli\u003eEnsure P1\/P2 68‑pin connectors are fully seated to maintain stable analog‑signal timing.\u003c\/li\u003e\n\u003cli\u003eRoute analog wiring separately from relay or solenoid conductors to avoid impedance coupling.\u003c\/li\u003e\n\u003cli\u003eInspect terminal screws and clamps periodically to ensure long‑term mechanical stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47904270713022,"sku":"IS200TCASH1ACB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200trlyh1bge-relay-output-board-uyvour4wj4n.png?v=1759055679","url":"https:\/\/www.autooiltech.com\/products\/ge-is200tcash1acb-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}