{"product_id":"ge-is200staih2acb-is230snaih2a-analog-input-terminal-board","title":"GE IS200STAIH2ACB（IS230SNAIH2A） Analog Input Terminal Board","description":"\u003cp\u003eConfigured for analog signal acquisition in Mark VIe control system architectures, the \u003cstrong\u003eGeneral Electric IS200STAIH2ACB(IS230SNAIH2A)\u003c\/strong\u003e (\u003cstrong\u003eIS200STAIH2ACB(IS230SNAIH2A)\u003c\/strong\u003e Analog Input Terminal Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog designation \u003cstrong\u003eIS200STAIH2ACB(IS230SNAIH2A)\u003c\/strong\u003e defines a specific hardware revision and terminal board pairing. The base identifier \u003cstrong\u003eIS200STAIH2ACB\u003c\/strong\u003e denotes the compact analog input terminal board assembly, while the parenthetical \u003cstrong\u003eIS230SNAIH2A\u003c\/strong\u003e indicates the corresponding I\/O pack module architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2ACB(IS230SNAIH2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGlobal Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-power module interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels (0-20 mA standard; one configurable to 0-200 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module executes high-performance control tasks across industrial networks while maintaining rigid timing characteristics. Key operational behaviors include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupporting deterministic network communication paths across Speedtronic platform architectures to maintain synchronized analog signal conversion.\u003c\/li\u003e\n\u003cli\u003eManaging I\/O density scaling efficiently through a compact DIN rail mount configuration equipped with high-density Euro-style terminal blocks.\u003c\/li\u003e\n\u003cli\u003eProcessing multi-transmitter configurations (two-wire, three-wire, four-wire, or externally powered) with jumper-selectable current and voltage input paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the configurable analog output options available on this terminal board?\u003c\/p\u003e\n\u003cp\u003eA: It provides 2 analog output channels operating at a standard 0-20 mA, with one channel independently configurable up to 0-200 mA.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200STAIH2ACB(IS230SNAIH2A) support hot-swapping within the Mark VIe control rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The modular terminal board and I\/O pack design allows unpowered or system-managed hot insertion and extraction when executed inside designated redundant controller topologies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the system rack power supply is completely de-energized and locked out (LOTO) prior to mounting or wiring the terminal board.\u003c\/li\u003e\n\u003cli\u003eSecure the DIN rail mount enclosure firmly within the control cabinet to maintain mechanical stability under plant vibration profiles.\u003c\/li\u003e\n\u003cli\u003eTerminate field transmitter wiring to the high-density Euro-style terminal blocks, verifying correct jumper settings for current or voltage input paths.\u003c\/li\u003e\n\u003cli\u003eVerify board identification via the onboard ID chip and check signal loop continuity prior to restoring 24 VDC system power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48215761027262,"sku":"IS200STAIH2ACB（IS230SNAIH2A）","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200STTCH2ABA_IS230SNTCH4A_5396e134-1ea8-4495-9852-04aeb7ed4b80.png?v=1785233038","url":"https:\/\/www.autooiltech.com\/products\/ge-is200staih2acb-is230snaih2a-analog-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}