{"product_id":"ge-is200spidg1aba-accessory-id-terminal-module","title":"GE IS200SPIDG1ABA Accessory ID Terminal Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200SPIDG1ABA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200SPIDG1ABA\u003c\/strong\u003e Accessory ID Terminal Module, operates as a dedicated hardware component for electronic identification and mechanical mounting within Mark VIe PROFIBUS-DP master communications networks. This terminal module provides the physical mounting chassis and localized ID data storage required to dock the IS220PPRFH1B PROFIBUS Master Gateway I\/O pack, permitting deployment of the communication sub-assembly into ordinary, non-hazardous field locations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200SPIDG1ABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (General Electric Speedtronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess than 0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard SPIDG1 compact terminal board footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard non-hazardous industrial enclosure limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via mated I\/O pack logic interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAccessory ID Terminal Module (SPID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe (compatible with select Mark VI systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMating Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated mounting port for IS220PPRFH units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eMetal Chassis mounting structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eGroup 1 normal style standard PCB coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Status\u003c\/td\u003e\n\u003ctd\u003e3 total revisions (Artwork: A, Functional: B, Functional: A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic ID\u003c\/td\u003e\n\u003ctd\u003eIntegrated on-board parameter read-only chip tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe installation of the IS200SPIDG1ABA hardware interface layer introduces zero attenuation or phase shifting to the serial data lines, ensuring the underlying backplane bus communication velocity remains at full factory rating. Its integrated electronic ID chip functions as a hardware-level node identifier that the docked gateway processor queries prior to initiating any downstream data routing or firmware flash operations. This automatic parameter cross-check ensures that the exact board revision and artwork configuration match the master controller specification, protecting the localized network topology against unauthorized or mismatched hardware configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the three total revisions of the IS200SPIDG1ABA terminal module completely backwards-compatible?\u003c\/p\u003e\n\u003cp\u003eA: No. Only the first two functional revisions of this module are designed to be backwards-compatible with preceding Mark VI series layouts. The later artwork configuration and functional revisions introduce changes that must be matched with compatible I\/O pack revisions to prevent hardware incompatibility faults.\u003c\/p\u003e\n\u003cp\u003eQ: Does this terminal board require an external DC power connection to operate its built-in electronic identification chip?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200SPIDG1ABA is a passive terminal board assembly. The on-board ID circuit and memory components receive localized logic-level operating power directly through the interface connector pins when the matching IS220PPRFH module is docked and powered.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Ground Continuity\u003c\/strong\u003e: Secure the module firmly to the metal chassis using the specified mechanical fasteners to establish a low-impedance path for integrated noise and surge suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Pack Docking Alignment\u003c\/strong\u003e: Position the IS220PPRFH module squarely over the board interface port before pressing down to prevent pin skew or deformation on the multi-pin connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Isolation\u003c\/strong\u003e: Ensure the unit is installed inside an ordinary, non-hazardous enclosure that meets the environmental sealing criteria for industrial master communication hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Clearness Check\u003c\/strong\u003e: Confirm that the surrounding metal chassis has adequate mechanical clearance to permit seamless insertion and tool access for the side jackscrews of the mated gateway module.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47589338611902,"sku":"IS200SPIDG1ABA","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200SPIDG1ABA_3.png?v=1780035509","url":"https:\/\/www.autooiltech.com\/products\/ge-is200spidg1aba-accessory-id-terminal-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}