{"product_id":"ge-is200jpdsg1acb-power-distribution-board","title":"GE IS200JPDSG1ACB Power Distribution Board","description":"\u003ch2\u003eGE IS200JPDSG1ACB Power Distribution Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for 28 V DC bus routing in Mark VIe power networks, the \u003cstrong\u003eGE IS200JPDSG1ACB\u003c\/strong\u003e (\u003cstrong\u003eIS200JPDSG1ACB\u003c\/strong\u003e Power Distribution Board) provides direct electrical distribution, bus jumpering, and diagnostic feedback for PPDA‑supervised power assemblies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200JPDSG1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e16.51 cm × 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePower Distribution Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eClass 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Buses\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eThree independent 28 V DC buses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInput Connectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eJR, JS, JT (bulk supply inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRack Supply Outputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eJCR, JCS, JCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eJPDP Outputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSix 3×2 Mate‑N‑Lok connectors (J1–J6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eJAR, JAS, JAT (PTC‑fused, common‑mode choke)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDiagnostic Connectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDual 50‑pin connectors (top\/bottom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePPDA Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDC‑62 connector, P4 diode‑ORed output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBus Access Terminals\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eTB1, TB2 (35 A continuous, 75 A ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDIN‑rail or direct metal holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licenses\u003c\/h3\u003e\n\u003cp\u003eAs part of GE’s Mark VIe power‑distribution platform, the IS200JPDSG1ACB aligns with deterministic cabinet‑level timing used for PPDA diagnostic polling. Ribbon‑cable communication provides fixed‑cycle updates for bus voltage, supply‑status contacts, and auxiliary‑circuit feedback. Firmware flash compatibility resides at the PPDA pack level; JPDS hardware behavior is static and non‑programmable. I\/O density scaling is achieved through JPDP and JPDL expansion, allowing multiple I\/O packs to be powered without altering backplane communication velocity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can JPDS be hot‑swapped while energized?\u003c\/strong\u003e A: No. The board must be handled only when the cabinet is de‑energized to avoid undefined bus states and relay disturbances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does JPDS introduce additional backplane load?\u003c\/strong\u003e A: JPDS draws power only from connected 28 V DC supplies. It does not impose atypical loading on the Mark VIe backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is bus jumpering performed?\u003c\/strong\u003e A: TB1 and TB2 provide screw‑terminal access to R, S, and T buses for controlled jumpering between boards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board using the vertical DIN‑rail holder or direct metal bracket, ensuring full mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eRoute JR\/JS\/JT supply wiring according to cabinet diagrams; maintain separation from high‑energy conductors.\u003c\/li\u003e\n\u003cli\u003eGround the board through the sheet‑metal bracket to the cabinet base; ensure clean bonding surfaces.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity for JPDP and auxiliary outputs to reduce noise on low‑level circuits.\u003c\/li\u003e\n\u003cli\u003eVerify 50‑pin diagnostic ribbon seating before energizing; loose connectors can disrupt PPDA feedback.\u003c\/li\u003e\n\u003cli\u003eInspect PTC fuses and common‑mode chokes on JAR\/JAS\/JAT during commissioning to confirm auxiliary‑circuit readiness.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48164603691198,"sku":"IS200JPDSG1ACB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is230jpdmg1b-remote-input-output-rio-module-exuyuzutokz.png?v=1759131953","url":"https:\/\/www.autooiltech.com\/products\/ge-is200jpdsg1acb-power-distribution-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}