{"product_id":"ge-is200jgpag1a-ground-and-power-terminal-board","title":"GE IS200JGPAG1A Ground and Power Terminal Board","description":"\u003ch2\u003eGE IS200JGPAG1A Ground and Power Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC field‑power distribution and shield termination within Mark VIe I\/O assemblies, the \u003cstrong\u003eGE IS200JGPAG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200JGPAG1A\u003c\/strong\u003e ground and power board, provides direct physical\/electrical execution. It delivers regulated excitation power for 4–20 mA field instruments and establishes a structured grounding path adjacent to PCAA and TCAT analog modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eIS200JGPAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e33 cm high x 3.2 cm wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eSupplied via 28 VDC feed from PCAA\/TCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore Performance\u003c\/th\u003e\n\u003ctd\u003eRegulated 24 VDC distribution and shield termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnology\u003c\/th\u003e\n\u003ctd\u003eThrough hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eGround and Power Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eWithin Mark VIe architectures, the board maintains deterministic backplane bus communication velocity by providing stable excitation power without introducing timing skew into analog acquisition cycles. I\/O density scaling is preserved through twelve independent regulators, preventing cross‑impact between powered transmitters. Firmware flash compatibility resides entirely at the PCAA\/TCAT module level; the JGPA board operates as fixed hardware with no programmable logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200JGPAG1A be removed while the panel is energized? A: Removal under power is not recommended. Disconnecting the board may interrupt excitation power and cause analog channel faults.\u003c\/p\u003e\n\u003cp\u003eQ: Does each 24 VDC output channel have isolation? A: Yes. Each channel is independently regulated to prevent cross‑impact between field devices.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board differentiate power terminals from shield terminals? A: TB3 uses orange terminals for 24 VDC outputs, while TB1 and TB2 use green terminals for shield termination.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board adjacent to PCAA or TCAT modules to minimize cable length and reduce noise pickup.\u003c\/li\u003e\n\u003cli\u003eEnsure correct orientation of the P1 cable supplying 28 VDC from the analog module.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between shield wiring and power conductors to reduce induced noise.\u003c\/li\u003e\n\u003cli\u003eFor conductive mounting, ensure metal‑to‑metal contact for direct grounding.\u003c\/li\u003e\n\u003cli\u003eFor isolated mounting, use non‑conductive hardware and route shield grounds to the designated grounding point.\u003c\/li\u003e\n\u003cli\u003eVerify terminal torque and labeling before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48232762474686,"sku":"IS200JGPAG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-30_10-41-59.png?v=1782787591","url":"https:\/\/www.autooiltech.com\/products\/ge-is200jgpag1a-ground-and-power-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}