{"product_id":"ge-is200iciah1abb-printed-circuit-board","title":"GE IS200ICIAH1ABB Printed Circuit Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eConfigured for signal conditioning and slot‑specific backplane interfacing in the Mark VI Speedtronic platform, the \u003cstrong\u003eGE IS200ICIAH1ABB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ICIAH1A\u003c\/strong\u003e PCB, provides direct electrical routing between its multi‑pin connectors, relays, and the VME‑based rack interface. The board executes fixed‑path signal transfer through its card‑edge connector and faceplate alignment hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe provided documentation does not define any suffix‑level segmentation for IS200ICIAH1ABB.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo model matrix can be generated without introducing unsupported assumptions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe suffix string is treated as a fixed, non‑decomposable identifier.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e IS200ICIAH1ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e GE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e IS200 domestic GE manufacturing code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Not specified (standard PCB with faceplate)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Not specified (VME rack form factor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e Not specified (use Mark VI cabinet environmental limits)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Not specified (depends on backplane load)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VI Speedtronic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Description:\u003c\/strong\u003e Printed Circuit Board for backplane interfacing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Normal Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRevision:\u003c\/strong\u003e Three revisions, backward‑compatible with first two\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCoating:\u003c\/strong\u003e Conformal PCB coating applied across base PCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e VME rack assembly via metal faceplate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e 24‑pin, 16‑pin, 20‑pin connectors; stab‑on connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComponents:\u003c\/strong\u003e Resistors, capacitors, MOVs, ICs, relays, fuses, diodes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Interface:\u003c\/strong\u003e Card‑edge connector for slot‑specific insertion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe IS200ICIAH1ABB aligns with GE Mark VI deterministic backplane bus timing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSlot addressing is fixed; incorrect placement can cause bus contention or physical damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe ICIA functional code indicates compatibility with Mark VI firmware flash structures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUpstream controller firmware revisions remain interoperable with earlier hardware revisions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCB routing supports I\/O density scaling through distributed component groupings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTrace layout minimizes cross‑trace interference during high‑speed backplane cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the IS200ICIAH1ABB be inserted or removed under power?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e No. Mark VI VME‑style boards do not support hot‑swap. Power must be removed before insertion or extraction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the conformal coating affect diagnostic probing?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Yes. The coating protects copper traces and components. Any probing requiring coating penetration should be performed only under controlled service procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Are there timing considerations when used in redundant Mark VI racks?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Yes. Redundant controllers depend on deterministic bus timing. The board must be installed in its exact designated slot to maintain synchronization and avoid failover delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintain ESD protection during handling; the board contains MOS‑sensitive ICs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInsert the board only into its assigned VME slot to avoid connector deformation or bus faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure the faceplate brackets fully seat against the rack chassis to maintain grounding continuity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApply strain relief to harnesses connected to the 24‑pin, 16‑pin, and 20‑pin connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBond shielded cables at a single grounding point to prevent ground‑loop interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify fuse and relay seating visually before energizing the rack after maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47812492165310,"sku":"IS200ICIAH1ABB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200wetbh1a-top-box-b-module-s2zxghgpddr.png?v=1759047133","url":"https:\/\/www.autooiltech.com\/products\/ge-is200iciah1abb-printed-circuit-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}