{"product_id":"ge-ic694mdl646-rx3i-dc-voltage-input-module","title":"GE IC694MDL646 RX3i DC Voltage Input Module","description":"\u003ch3\u003e\n\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eDescription\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IC694MDL646\u003c\/strong\u003e RX3i DC Voltage Input Module is a rack-based I\/O component used in PACSystems RX3i programmable automation controllers. It is engineered for mission-critical discrete and process applications, offering advanced diagnostics and flexible integration with field devices such as limit switches, push buttons, and proximity sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\/Part Number:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL646\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 32-point DC voltage input (positive logic)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 0–30 VDC (typical operating range 20–30 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 6.5 mA per channel @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 3.5 kΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLogic Levels:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eON: \u0026gt;11 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOFF: \u0026lt;5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 1 ms ON \/ 1 ms OFF filter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC between field side and logic side\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e 80 mA @ 5 VDC, 125 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 34 × 145 × 140 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.26 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL 508, CSA C22.2 No. 142M1987, Class I Div. 2 Hazardous Locations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring discrete signals from industrial sensors and switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed digital input acquisition in manufacturing automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess control systems requiring reliable 24 VDC input monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergy, water treatment, and transportation industries      \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can IC694MDL646 be hot-swapped?\u003c\/strong\u003e A: Yes, it supports hot insertion\/removal within RX3i racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of devices can be connected?\u003c\/strong\u003e A: Limit switches, push buttons, proximity sensors, and other 24 VDC discrete devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is it backward compatible with Series 90-30 modules?\u003c\/strong\u003e A: Yes, RX3i backplanes support legacy Series 90-30 I\/O modules.\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46243218882750,"sku":"IC694MDL646","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ge-fanuc-ic694mdl940-voltage-output-module-jnxdfgljne1_3aa5ff06-f7a3-4137-929e-b564ee642c9d.png?v=1775716255","url":"https:\/\/www.autooiltech.com\/products\/ge-ic694mdl646-rx3i-dc-voltage-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}