{"product_id":"ge-ic670chs101-field-control-i-o-terminal-block-base","title":"GE IC670CHS101 Field Control I\/O Terminal Block Base","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC670CHS101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC670\u003c\/strong\u003e Field Control I\/O Terminal Block, operates as a dedicated hardware component for physical field wiring termination and module hosting within Field Control I\/O stations. The structural base unit provides a heavy-duty physical interface layer natively at the hardware tier to route field signals directly into matching plug-in electronic modules while supporting live network maintenance.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670CHS101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.09 lbs (0.49 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eModular block base chassis layout optimized for tight cabinet footprints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C standard industrial operational tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C absolute storage limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Style\u003c\/td\u003e\n\u003ctd\u003eBarrier-style terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003eDedicated physical screw points for discrete\/analog field connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Support\u003c\/td\u003e\n\u003ctd\u003eEngineered for hot insertion and removal of operational modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN-rail structure compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Structural Scaling\u003c\/strong\u003e The base incorporates a passive parallel backplane bus framework within its heavy-duty substrate. When an electronic module is mounted onto this terminal block base, it bridges directly into the local Bus Interface Unit (BIU) network routing layout. The internal tracking geometry ensures zero signal propagation delays, allowing input and output data words to update across deterministic network cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Insertion Logic Shielding\u003c\/strong\u003e The mechanical and electrical footprint is engineered with a specialized pin configuration layout that handles hot insertion and removal protocols safely. This physical configuration allows operators to extract or swap faulted logic modules during live system execution without introducing transient spikes, voltage sags, or data packet corruption across adjacent active slots on the shared network bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary physical benefits of the barrier terminal strips on this specific base?\u003c\/p\u003e\n\u003cp\u003eA: The barrier terminal design implements physical, non-conductive plastic walls between each independent screw termination point. This structure minimizes the risk of accidental short circuits caused by stray wire strands or tools during field installation, commissioning, or hot-swap maintenance loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC670CHS101 terminal base be replaced while the rest of the I\/O rack is powered up?\u003c\/p\u003e\n\u003cp\u003eA: No, while individual electronic I\/O modules plugged into the top of this base support hot insertion, the IC670CHS101 itself forms the underlying backplane segment. Removing or unseating the base unit breaks the internal parallel bus routing and will drop power and communications to all subsequent downstream modules in that rack assembly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47673645924542,"sku":"IC670CHS101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-18_10-18-10_11986cd7-a33c-4f95-89c8-913ea4610a9e.png?v=1781750142","url":"https:\/\/www.autooiltech.com\/products\/ge-ic670chs101-field-control-i-o-terminal-block-base","provider":"AutoOilTech Limited","version":"1.0","type":"link"}