{"product_id":"ge-ic670alg330-output-module","title":"GE IC670ALG330 Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC670ALG330\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC670\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for continuous variable signal generation within Field Control I\/O stations. The sub-assembly drives 8 single-ended current source outputs natively at the hardware tier to actuate control valves, variable speed drives, and analog chart recorders across modular expansion frameworks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 lbs (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eField I\/O control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e8 Current Source outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Nominal\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.48 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital-to-Analog Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits (0.3125 uA per count maximum resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnitude Data Size\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e1 LSB resolution value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms typical per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e2000 pF maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Inductance\u003c\/td\u003e\n\u003ctd\u003e0.5 H maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Wire Threshold\u003c\/td\u003e\n\u003ctd\u003e1.0 mA minimum, 3.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Isolation Limit\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute \/ 250 VAC continuous (to ground and logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC typical (18 to 30 VDC allowable range, 10% maximum ripple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBIU Power Consumption\u003c\/td\u003e\n\u003ctd\u003e85 mA maximum current drawn from Bus Interface Unit backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA maximum drawn from external supply (all 8 outputs at 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Diagnostics\u003c\/td\u003e\n\u003ctd\u003e1 LED indicator (Steady = OK, Flashing = Fault, Off = No Power\/Fatal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Signal Scaling\u003c\/strong\u003e The onboard Digital-to-Analog Converters (DAC) receive digital registers scaled in engineering units from the local Bus Interface Unit (BIU) via the passive parallel backplane structure. The internal processing logic parses incoming data words, applies stored flash-memory calibration configurations, and updates all 8 analog channel current tracks within a typical 1.5 ms execution window to preserve deterministic control loop velocities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Fault State Containment\u003c\/strong\u003e The module integrates intelligent hold-last-state parameters configurable per channel. If a backplane power drop occurs, the module watchdog timer expires, or no data packets are received from the BIU within the timeout period, the hardware automatically locks the active current outputs to their last valid value, dropping DAC operational resolution from 16 bits to 14 bits to maintain output stability during network recovery windows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What technical fault diagnostics trigger an alarm flag on the IC670ALG330?\u003c\/p\u003e\n\u003cp\u003eA: The internal processing architecture continually validates output loop continuity. The hardware generates distinct diagnostic alarm registers and passes error codes across the backplane bus to the BIU when encountering under-range signals, over-range exceptions, or an open-wire field fault where current falls below the 1.0 to 3.5 mA threshold.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module calibration parameters be recovered if the configuration becomes corrupted?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features on-board non-volatile flash memory that archives the factory calibration data baselines. Users can clear custom field scaling parameters via configuration commands to restore the module directly to its factory-calibrated current output settings.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":47673645760702,"sku":"IC670ALG330","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-18_09-56-07_6d6dc2b7-93dd-4437-ad75-187c2e6b9155.png?v=1781750103","url":"https:\/\/www.autooiltech.com\/products\/ge-ic670alg330-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}