{"product_id":"ge-ic660bbs103-genius-discrete-i-o-block","title":"GE IC660BBS103 Genius Discrete I\/O Block","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC660BBS103\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660BBS103\u003c\/strong\u003e Discrete I\/O Block, operates as a dedicated hardware component for multi-voltage signal processing, solid-state load modulation, and advanced branch circuit diagnostics within Genius network architectures. The intelligent distributed module executes native electronic monitoring and channel protection directly at the hardware tier to drive highly inductive or resistive industrial actuators without secondary auxiliary terminal relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660BBS103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eGenius I\/O System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e3.44 lbs (1.56 kg) physical weight \/ 4 lbs (1.80 kg) shipping allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.44 cm x 8.48 cm x 9.93 cm (8.83 in x 3.34 in x 3.91 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Density\u003c\/td\u003e\n\u003ctd\u003e8 configurable input\/output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Topology\u003c\/td\u003e\n\u003ctd\u003e4 isolated groups of 2 circuits; 1500 V block-to-block galvanic barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltages\u003c\/td\u003e\n\u003ctd\u003e115 VAC (47 to 63 Hz) \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range Limits\u003c\/td\u003e\n\u003ctd\u003e93 to 132 VAC \/ 105 to 132 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Dropout Window\u003c\/td\u003e\n\u003ctd\u003e1 full cycle on AC line \/ 10 ms maximum duration on DC line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Output Current\u003c\/td\u003e\n\u003ctd\u003eAC: 2 A RMS; DC: 2 A resistive \/ 1 A inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Block Output Thresholds\u003c\/td\u003e\n\u003ctd\u003e15 A maximum at 35 deg C \/ 7.5 A maximum at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Electronic Fusing\u003c\/td\u003e\n\u003ctd\u003eShort-circuit trip response: 100 ms (AC) \/ 10 ms (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Processing Base Latency\u003c\/td\u003e\n\u003ctd\u003e2 ms for AC operations \/ 0.8 ms for DC operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Input Filter Time\u003c\/td\u003e\n\u003ctd\u003e10 to 100 ms adjusted in 10 ms increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e16.8 W with all inputs active \/ 45.6 W with all outputs loaded at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Vibrational Rating\u003c\/td\u003e\n\u003ctd\u003e5 to 10 Hz operating frequency at 0.2 inches of physical displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Envelope\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (+32 to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Limits\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Hardware Diagnostics\u003c\/td\u003e\n\u003ctd\u003eFaceplate indicators (Unit OK, I\/O Enabled) and individual channel LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer; standard replacement for IC660BBS101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Network Scanning\u003c\/strong\u003e The intelligent block communicates over a single shielded twisted-pair Genius token-passing bus, relaying 8-point register blocks straight to host controllers at speeds up to 153.6 kbaud. This independent data layer processes bit-level diagnostic words and programmable input filters parallel to the central processing unit's master logic scan, avoiding data pipeline congestion during critical synchronization updates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Isolated Group Routing\u003c\/strong\u003e The hardware design optimizes density scaling by compressing 8 universal circuits onto a rugged, compact field-mountable baseplate. The 8 circuits are split into 4 isolated groups of 2 channels each, enabling different voltage phases or independent DC potentials to reside on the same block footprint without cross-talk or common-mode signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What precise electronic diagnostic responses manifest if an output line experiences a no-load fault?\u003c\/p\u003e\n\u003cp\u003eA: The module constantly monitors current conduction through the internal solid-state switches. If an output channel is commanded to the active state but current flow remains below the minimum threshold, the block senses a no-load condition, flags an open field-wire error register on the Genius bus, and sets the local diagnostic LED.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC660BBS103 module be extracted from its terminal assembly while the parent Genius bus is actively polling?\u003c\/p\u003e\n\u003cp\u003eA: The mechanical separation mechanism allows the electronic control assembly to be safely unseated from its pre-wired terminal block base plate. However, pulling the active component under load is restricted unless proper lock-out precautions are executed, as the primary serial link continuity downstream depends on the specific bus wiring configuration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":47693162578110,"sku":"IC660BBS103","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-22_10-15-28_66d947de-a843-4721-8448-a8d9f610b627.png?v=1782097053","url":"https:\/\/www.autooiltech.com\/products\/ge-ic660bbs103-genius-discrete-i-o-block","provider":"AutoOilTech Limited","version":"1.0","type":"link"}