{"product_id":"ge-fanuc-ur-6lh-ur-6lh-digital-i-o-module","title":"GE Fanuc UR 6LH UR-6LH Digital I\/O Module","description":"\u003ch2\u003eGE Multilin UR‑6LH Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital signal acquisition and control within Universal Relay (UR) systems, the \u003cstrong\u003eGE Multilin UR‑6LH\u003c\/strong\u003e (\u003cstrong\u003eUR‑6LH\u003c\/strong\u003e digital I\/O module) provides two Form‑A outputs, two Form‑C outputs, and eight digital inputs. The module supports wet or dry contact operation and integrates directly with UR backplane logic for protection, interlocking, and auxiliary control functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUR‑6LH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2 lb 9 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eapprox. 15 cm L × 18 cm W × 4 cm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003eNot specified (UR‑series ambient norms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eHigh‑power digital I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Type\u003c\/th\u003e\n\u003ctd\u003eMixed digital I\/O (Form‑A, Form‑C, digital inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Count\u003c\/th\u003e\n\u003ctd\u003e2 Form‑A outputs, 2 Form‑C outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Count\u003c\/th\u003e\n\u003ctd\u003e8 digital inputs (wet or dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring\u003c\/th\u003e\n\u003ctd\u003eOptional current metering; optional voltage metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSoftware Support\u003c\/th\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eDigital I\/O module for UR Universal Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eUR‑series digital I\/O modules rely on deterministic backplane timing to ensure predictable input sampling and output activation. The UR‑6LH’s high‑power design maintains stable rail loading, preventing timing drift during simultaneous multi‑card operations. I\/O density scaling across UR frames allows mixed Form‑A, Form‑C, fast Form‑C, latching, and SSR cards to coexist without firmware flash incompatibility, provided modules remain in their original slot positions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the UR‑6LH be hot‑swapped while the relay remains energized? A: No. Control power must be removed before insertion or extraction to avoid unintended output transitions and backplane state faults.\u003c\/p\u003e\n\u003cp\u003eQ: Does the UR‑6LH impose any special backplane current requirements? A: As a high‑power digital I\/O module, it draws more rail current than low‑power variants, but remains within UR‑series backplane limits.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware updates required when replacing a UR‑6LH with another 6L‑family module? A: No firmware resides in the module. Slot position must be preserved, but configuration remains at the relay CPU.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemove control power before handling the module.\u003c\/li\u003e\n\u003cli\u003eOpen the hinged front panel fully to access module bays.\u003c\/li\u003e\n\u003cli\u003eRecord the original slot position; UR modules must be replaced in the same location.\u003c\/li\u003e\n\u003cli\u003eUse inserter clips to slide the module smoothly into the bay and ensure both clips lock simultaneously.\u003c\/li\u003e\n\u003cli\u003eMaintain clean connector surfaces to ensure stable backplane seating.\u003c\/li\u003e\n\u003cli\u003eFollow ESD precautions when accessing relay internals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48170756735166,"sku":"UR6LH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-06_10-09-43_452b1160-d07f-44c8-925b-472efae1c038.png?v=1783304778","url":"https:\/\/www.autooiltech.com\/products\/ge-fanuc-ur-6lh-ur-6lh-digital-i-o-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}